White Rodgers 1F95-1280 Wiring Diagrams, Single Stage or Multi-Stage System, Heat Pump Systems

Models: 1F95-1280

1 16
Download 16 pages 35.48 Kb
Page 3
Image 3
WIRING DIAGRAMS

WIRING DIAGRAMS

Figure 2 – Single Stage or Multi-Stage System

(No Heat Pump) with Single Transformer

System

RC

RH

C

Y

Y2

W/E

W2

G

O/B

6

L

 

 

 

 

 

 

 

 

 

 

 

 

Single Stage 1

 

 

 

Call for cool

No Output

Call for heat

No output

 

Installer

 

 

(SS1)

 

 

 

 

 

 

 

 

Configuration

 

“Call for Service”

 

 

 

 

 

 

 

 

 

Menu selects

 

 

 

 

24 volt

 

 

 

 

 

 

(malfunction

 

 

 

 

 

 

 

 

“O” or “B” for

 

 

 

 

common

 

 

 

 

Blower/Circulator fan

 

indicator) for

 

 

 

 

 

 

 

changeover

Power closed

 

24 volt

24 volt

(optional

 

 

 

 

energized on a call

Heat Pumps

 

 

 

 

 

function. Set

 

for system

 

 

 

 

for cool or Fan On

connection for

with “L” terminal

 

power for

power for

 

 

 

 

to “O” terminal

SPDT 3-wire

 

cooling

heating

operation,

 

 

 

 

(also energized in

energized in Cool

connection.

 

required

Cool mode-1st

 

Heat mode-1st

Heat mode-2nd

heating if configured

zone valve

Multi Stage 2

 

 

Cool mode-2nd

& Off mode. Set

Original production

 

 

for remote

for Electric Heat)

 

(MS2)

 

 

stage

stage

stage

stage

to “B” terminal

 

1F95-1291’s

 

 

sensor)

 

 

 

 

 

 

 

 

 

 

energized in

 

do not have this

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat & emergency

 

connection

 

 

 

 

 

 

 

 

 

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEUTRAL

 

 

 

 

 

24VAC

 

 

 

120VAC

HOT

 

 

 

 

 

 

 

 

 

 

Single Stage and Multi-Stage Connections

SINGLE STAGE (SS 1) gas, oil or electric.

 

 

 

CLASS II

Refer to equipment manufacturers’ instructions for specifi c system

 

MULTI-STAGE (MS 2) gas, oil or electric.

TRANSFORMER

wiring information.

 

 

 

 

 

 

 

This thermostat is designed to operate a single-transformer or two-

After wiring, see INSTALLER CONFIGURATION section for proper

transformer system.

thermostat confi guration.

 

 

 

You can confi gure the thermostat for use with the following fossil fuel

 

 

 

 

systems:

 

 

 

 

Figure 3 – Heat Pump Systems

System

RC

RH

C

Y

Y2

*W/E

*W2

G

O

6

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat mode-2nd

Heat mode-3rd

 

 

 

 

 

 

 

 

 

 

stage, Emergency

stage, Emergency

 

 

 

 

Heat

 

 

 

 

 

Mode-1st stage

Mode-2nd stage

 

 

 

 

 

 

 

 

 

*Note: Dual Fuel

*Note: Dual Fuel

 

 

 

 

Pump 1

 

 

 

 

No Output

 

 

 

 

 

 

 

 

option de-

option de-

 

 

 

 

(HP1)

 

 

 

 

 

Installer

 

 

 

 

 

 

 

energizes Heat

energizes Heat

 

 

 

 

 

 

 

 

 

mode stage 1

mode stage 1

 

Configuration

 

“Call for Service”

 

 

 

24 volt

 

 

(compressor)

(compressor)

 

Menu selects

 

 

 

 

 

 

 

 

(malfunction

 

 

 

 

 

when auxiliary

when auxiliary

 

“O” or “B” for

 

 

 

 

common

 

 

Blower/Circulator fan

 

indicator)

 

 

 

Heat mode-1st

 

heat is energized

heat is energized

changeover

Power closed

 

24 volt

24 volt

(optional

stage,

 

 

 

energized on a call

function. Set

connection for

for Heat Pumps

 

for system

 

 

 

for cool or Fan On

with “L” terminal

 

power for

power for

Cool mode-1st

 

 

 

to “O” terminal

 

operation,

 

Heat mode-3rd

Heat mode-4th

(also energized in

SPDT 3-wire

connection.

 

cooling

heating

required

stage,

 

heating if configured

energized in Cool

zone valve

Original production

 

 

 

(Compressor)

 

stage, Emergency

stage, Emergency

& Off mode. Set

 

 

 

 

for remote

 

 

Mode-1st stage

Mode-2nd stage

for Electric Heat)

to “B” terminal

 

1F95-1291’s

 

 

 

sensor)

 

 

 

 

do not have this

Heat

 

 

 

Heat mode-2nd

 

 

 

energized in

 

 

 

 

 

*Note: Dual Fuel

*Note: Dual Fuel

 

 

connection

 

 

 

 

 

Heat &

 

Pump 2

 

 

 

 

stage,

 

 

 

 

 

 

 

option de-

option de-

 

emergency mode

 

 

(HP2)

 

 

 

 

Cool mode-2nd

 

 

 

 

 

 

 

energizes Heat

energizes Heat

 

 

 

 

 

 

 

 

 

stage,

 

 

 

 

 

 

 

 

 

mode stages 1

mode stages 1

 

 

 

 

 

 

 

 

 

(Compressor)

 

 

 

 

 

 

 

 

 

and 2 (both

and 2 (both

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

compressors)

compressors)

 

 

 

 

 

 

 

 

 

 

when auxiliary

when auxiliary

 

 

 

 

 

 

 

 

 

 

heat is energized

heat is energized

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEUTRAL

 

 

 

 

 

 

120VAC

120VAC

 

24VAC

 

 

 

 

HEATING

HOT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLASS II

 

 

TRANSFORMER

NEUTRAL

 

 

 

 

 

 

 

 

 

 

 

 

24VAC

 

 

 

 

 

 

 

 

 

 

120VAC

HOT

 

 

 

 

 

 

 

 

 

 

COOLING

 

 

 

 

*Dual fuel option, if selected turns off compressor(s) when Auxiliary stages energize.

 

 

 

 

 

 

 

 

 

 

 

 

CLASS II

 

TRANSFORMER

Heat Pump Connections

If you do not have a heat pump system, refer to fi gure 3.

Refer to equipment manufacturers’ instructions for specifi c system wiring information.

You can confi gure the thermostat for use with the following heat pump systems.

HEAT PUMP TYPE 1 (HP 1). Single stage compressor system; gas or electric backup.

HEAT PUMP TYPE 2 (HP 2). Multi-stage compressor or two compressor system with gas or electric backup.

After wiring, see INSTALLER CONFIGURATION section for proper thermostat confi guration.

Figure 4 – Damper Terminal and Sensors

A1

Damper or

Economizer

Operation

(see configuration

menu item 31)

+

S

-

 

 

 

Supply voltage

Remote

Supply voltage

to remote

temperature

to remote

temperature

sensor signal

temperature

sensor

 

sensor

 

 

 

3

Page 3
Image 3
White Rodgers 1F95-1280 Wiring Diagrams, Single Stage or Multi-Stage System, No Heat Pump with Single Transformer