INSTALLER/CONFIGURATION MENU

INSTALLER/CONFIGURATION MENU

Press and hold the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press Menu to ad-

vance to the next menu item. Press Manual backgroundManual backgroundManual background or Manual backgroundManual backgroundManual backgroundManual background to change a menu item options.

INSTALLER/CONFIGURATION MENU

MENU

PRESS

DISPLAYED

Press

 

 

 

or

 

 

 

 

to

COMMENTS

 

 

 

 

 

 

 

REF.

BUTTON

(FACTORY DE-

select from listed op-

 

 

 

FAULT)

 

 

tions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

MENU

(GAS)

 

 

ELE

 

GAS setting: furnace controls the blower

 

 

 

 

 

 

 

 

 

 

 

 

 

ELE setting: thermostat controls the blower

 

 

 

 

 

 

 

 

 

 

 

 

 

2

MENU

CS (3)

0, 1, 2, 4, 5, 6

 

Selects Cool Savings

 

 

 

 

 

 

 

 

 

 

 

 

 

Value 1 (low) to 6 (high),

 

 

 

 

 

 

 

 

 

 

 

 

 

Value 0 disables feature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

MENU

E (On)

 

 

OFF

 

Selects Energy Management Recovery (EMR)

 

 

 

 

 

 

 

 

 

 

 

 

 

On or OFF.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

MENU

CR Heat (ME)

 

SL, FA

 

Adjustable Anticipation:

 

 

 

 

 

 

 

 

 

 

 

 

 

Selects heating cycle rate for MS or SS in #1 only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

MENU

CR Cool (ME)

 

SL, FA

 

Adjustable Anticipation:

 

 

 

 

 

 

 

 

 

 

 

 

 

Selects the cycle rate for cooling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

MENU

CL (OFF)

 

CL On

 

Compressor Lockout Time

 

 

 

 

 

 

 

 

 

 

 

 

7

MENU

Cool Off, Heat Auto

Heat Auto Cool Off,

System Mode Confi guration

 

 

 

Heat Off with Fan icon,

with Automatic Changeover capability

 

 

 

Heat Off without Fan icon

 

 

 

 

Cool Off, Auto Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

MENU

dL (On)

 

dL OFF

 

Selects Display Light On or OFF

 

 

 

 

 

 

 

 

 

 

 

 

9

MENU

0

1 HI, 2 HI, 3HI, 4 HI,

Adjustable Ambient Temperature Display

 

 

(current temperature)

1 LO, 2 LO, 3 LO, 4 LO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

MENU

°F

 

 

°C

 

Selects Fahrenheit/Celsius Temperature Display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

MENU

(On) b

 

 

OFF

 

May select Beeper OFF to stop audible

 

 

 

 

 

 

 

 

 

 

 

 

 

key feedback

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

MENU

P (7)

 

3, 0

 

 

 

 

 

Defaults 7-day programming (P7) but non-

 

 

 

 

 

 

 

 

 

 

 

 

 

programmable (0) or 5/1/1 programming (P3)

 

 

 

 

 

 

 

 

 

 

 

 

 

is available on most models.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

MENU

PS (4)

 

2

 

 

 

 

 

Selects Program periods per day:

 

 

 

 

 

 

 

 

 

 

 

 

 

4 = Morn, Day, Eve, Night

 

 

 

 

 

 

 

 

 

 

 

 

 

2 = Day, Night

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

MENU

Heat AS (On)

 

 

OFF

 

Automatic Schedule for heat mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

MENU

Cool AS (On)

 

 

OFF

 

Automatic Schedule for cool mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

MENU

Remote (OFF)

 

 

On

 

Selects Remote Sensor On/OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MENU

Remote

 

Outdoor

 

Selects Remote Sensor to outdoor

 

 

(In)

 

 

 

 

 

 

 

 

 

 

NA is Remote Sensor OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MENU

Indoor Loc

 

 

OFF

 

Selects Local Sensor (in thermostat) to OFF.

 

 

(On)

 

 

 

 

 

 

 

 

 

 

N/A if Remote is selected to Outdoor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

MENU

dS (On)

 

 

Off

 

Selects Automatic Daylight Saving Time option

 

 

 

 

 

 

 

 

 

 

 

 

 

18

MENU

(OFF)

L, P, Limit

 

Selects one of 3 Keypad Lockout confi gurations

 

 

Keypad Lockout

 

 

 

 

 

 

 

 

 

 

L - Total Keypad Lockout

 

 

 

 

 

 

 

 

 

 

 

 

 

P - Partial Keypad Lockout

 

 

 

 

 

 

 

 

 

 

 

 

 

(Up and Keys still work)

 

 

 

 

 

 

 

 

 

 

 

 

 

Limit - Limited Temperature RANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MENU

(000)

 

1-999

 

 

 

 

 

Selects personal lockout code. 000 is NOT A

 

 

Keypad Lockout

 

 

 

 

 

 

 

 

 

 

VALID CODE.

 

 

 

 

 

 

 

 

 

 

 

 

 

19

MENU

L Heat

L 62 to L 98

 

Selects Limited HEAT Range Temperature

 

 

(99)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

MENU

L Cool

L 46 to L 82

 

Selects Limited COOL Range Temperature

 

 

(45)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5