INSTALLATION

INSTALLATION

The Dual-Level Temp relay may be mounted in any position without affecting it's performance.

It can be connected using the 1/2" male conduit hub and

can be mounted to any standard junction box or wiring compartment.

It can also be mounted using the two holes in the back of the case. Location of the mounting holes may be simplified by holding the control against the mounting surface and marking the proper position for drilling the holes.

4 15/16"

Fig. 1. Dimensions of Type 24A06 Dual Level Temp 1 3/32"WIRING AND OPERATION

3 25/32"

2 1/8"

9/32"

3 15/32"

9/16"

3/8"

 

 

 

 

9/32"

7/32"

 

 

 

 

3 1/16"

9/16"

Connection Table1/2" STD CONDUIT HUB

OPERATION1 3/32"

Fig. 1. Dimensions of Type 24A06 Dual Level Temp

WIRING AND OPERATION

All wiring should be done in accordance with local and national electrical codes and ordinances.

If a wiring diagram is supplied with the heating equipment, follow those instructions. If none is available, two diagrams are presented which show different wiring methods for the Silent Operator relay.

NOTE

Use thermostat with a .4A fixed heater, or set adjustable heater in thermostat at .4A.

TYPE 24A06 DUAL LEVEL TEMP

WR

2-WIRE

HEATING THERMOSTAT

Connection Table

2-Wire Thermostat (R & W)

Black w/White stripe and

 

White to terminal W. Red to

 

terminal R.

 

 

Power Input:

Black & Blue

 

 

Heat Load 1:

Red & L2

 

 

Heat Load 2:

Black w/Red stripe & L2

 

 

OPERATION

As the thermostat closes its contacts, bimetal heaters #1 and #2 are energized. Approximately 45 seconds later, the warp- ing action of these heaters closes line voltage switches #1 and #2 to energize heating loads #1 and #2.

When the thermostat opens its contacts, bimetal heaters #1 and #2 cool for approximately 45 seconds before line voltage switches #1 and #2 open to de-energize the heating loads.

HEATING

LOAD #1

 

BLACK

WHITE

W/WHITE

STRIPE

RED

 

BIMETAL

BIMETAL

HEATER #1

HEATER #2

SWITCH #1

TRANSFORMER

SWITCH #2

BLACK W/RED STRIPE

R

 

RED W/BLACK STRIPE

 

E

 

 

D

B

 

 

 

 

 

 

 

 

L

 

 

 

 

A

 

 

 

 

C

 

 

HEATING

 

 

 

LOAD #2

 

K

 

 

 

B

 

 

 

 

L

 

 

 

 

U

 

L1

L2

 

E

 

 

WIRING

LINE

 

 

 

 

 

Line Voltage

Line Voltage Field

Low Voltage

Low Voltage Field

L1Fig. 2. Using Two-wire Heating Thermostat toL2

LINE

 

Fig. 2. Using Two-wire Heating Thermostat to

2

Operate Two Separate Heating Loads

 

Page 2
Image 2
White Rodgers 24A06G-1 Installation, Wiring And Operation, Dimensions of Type 24A06 Dual Level Temp, Connection Table