Image 1
Blue 4” Universal Thermostat with

Blue 4” Universal Thermostat with

Automatic Heat/Cool Changeover Option

Single Stage, Multi-Stage or Heat Pump

Installation and Operating Instructions for Model:

Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

Model

Programming Choice

 

 

1F83-0471

Non-Programmable

 

 

APPLICATIONS

THERMOSTAT APPLICATION GUIDE

 

1F83-0471 Thermostat

 

 

Description

 

 

 

 

 

Heat Pump (No Aux. or Emergency Heat)

Yes

 

Heat Pump (with Aux. or Emergency Heat)

Yes

 

Systems with up to 2 Stages Heat, 2 Stages Cool

Yes

 

Heat Only Systems (with optional fan switch)

Yes

 

Millivolt Heat Only Systems – Floor or Wall Furnaces

Yes

 

Cool Only Systems

Yes

 

Gas or Oil Heat

Yes

 

Electric Furnace

Yes

 

Hydronic (Hot Water) Zone Heat – 2 Wires

Yes

 

Hydronic (Hot Water) Zone Heat – 3 Wires

Yes

 

Compressor with Comfort Alert II Module (1F85CA only)

Yes

 

 

 

 

SPECIFICATIONS

Electrical Rating:

 

 

 

 

Battery Power

mV to 30 VAC, NEC Class II, 50/60 Hz or DC

Input-Hardwire

20 to 30 VAC

 

Terminal Load

1.5

A per terminal, 2.5A maximum all terminals combined

Setpoint Range

45° to 90°F (7° to 32°C)

Rated Differentials:

Fast

Med.

Slow

Heat (Single Stage/Multi Stage)

0.4

°F

0.6 °F

1.7 °F

Cool (Single Stage/Multi Stage)

0.9

°F

1.2 °F

1.7 °F

Heat Pump

0.9

°F

1.2 °F

1.7 °F

Aux. Heat

0.6

°F

1.7 °F

Operating Ambient

32° to +105°F (0° to +41°C)

Operating Humidity

90% non-condensing max.

Shipping Temperature Range

-40° to +150°F (-40° to +65°C)

Dimensions Thermostat

3-7/8”H x 5-1/8”W x 1-1/4”D

!CAUTION

To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.

Index

Page

Installation

2

Wiring Connections

2

Wiring Diagrams

3

Thermostat Quick Reference

4

Installer Configuration Menu

5

Operating Your Thermostat

7

Troubleshooting

7

ATTENTION: MERCURY NOTICE

This product does not contain mercury. However, this product may replace a product that contains mercury.

Mercury and products containing mercury must not be discarded in household trash. Do not touch any spilled mercury. Wearing non-absorbent gloves, clean up any spilled mercury and place in a sealed container. For proper disposal of a product containing mercury or a sealed container of spilled mercury, place it in a suitable shipping container. Refer to www.white-rodgers.comfor location to send product containing mercury.

 

PART NO. 37-7237A