White Rodgers 5059 installation instructions Installation Instructions, Description, Precautions

Models: 5059

1 4
Download 4 pages 1.64 Kb
Page 1
Image 1

WHITE-RODGERS

5059

Pilot Relight Control

 

INSTALLATION INSTRUCTIONS

 

 

Operator: Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BE- FORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PER- SONAL INJURY AND/OR PROPERTY DAMAGE.

The 5059 Pilot Relight Control is a low voltage control that generates ignition sparks. It is energized by the thermo- stat on a call for heat. Once flame is established, the control senses the flame and stops sparking. If the pilot flame is extinguished during a call for heat, the relight control will begin sparking immediately upon sensing absence of flame. The control delivers very low current sparks (approximately 6,000 volts).

DESCRIPTION

WHITE-

C

 

 

A

 

 

EMERSON

 

I O N

 

U

 

RODGERS

T

 

 

ELECTRIC

 

 

 

DIV.

 

If in doubt whether you wiring is millivolt, line, or low voltage, have it inspected by a qualified heating and air conditioning contractor, electrician, or someone familiar with basic electricity and wiring.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and ordinances.

This control is a precision instrument, and should be handled carefully. Rough handling or distorting compo- nents could cause the control to malfunction.

!CAUTION

To prevent electrical shock and/or equipment damage, disconnect electrical power to the sys- tem, at the main fuse or circuit box, until installa- tion is complete.

PRECAUTIONS

!CAUTION

Label all wires prior to disconnection when ser- vicing controls. Wiring errors can cause improper and dangerous operation.

Following installation or replacement, follow appliance manufacturer’s recommended instal- lation/service instructions to insure proper op- eration.

This control is not intended for use in locations where it may come in direct contact with water. Suitable protection must be provided to shield the control from exposure to water (dripping, spraying, rain, etc.).

!WARNING

Do not use on circuits exceeding specified volt- age. Higher voltage will damage the control and may cause shock or fire hazard.

 

 

 

 

 

 

 

 

 

SPECIFICATIONS

Electrical Rating:

Mounting:

 

 

 

 

 

 

24 VAC (30 VAC max.)

Surface mount or 2” x 4” switch box

 

 

 

 

 

60 Hz

 

 

 

 

 

 

 

0.030 Amps

Ambient Temperature Range:

 

 

 

 

 

 

 

 

-40°F to +175°F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHITE-RODGERS DIVISION

 

PART NO. 37-4778B

 

 

 

 

 

 

 

 

 

 

 

 

 

EMERSON ELECTRIC CO.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9797 REAVIS ROAD

Printed in U.S.A.

Replaces Part No. 37-4778A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ST. LOUIS, MISSOURI 63123-5398

 

9514

 

 

 

 

 

 

 

 

Page 1
Image 1
White Rodgers 5059 installation instructions Installation Instructions, Description, Precautions