White Rodgers 50A55-743 installation instructions Installation Instructions, Description

Models: 50A55-743

1 8
Download 8 pages 51.07 Kb
Page 1
Image 1
50A55-743

50A55-743

Integrated Furnace Control

INSTALLATION INSTRUCTIONS

FAILURETO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

The 50A55-743 is an automatic gas interrupted ignition control that employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan.

Signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shut-off during normal operation.

These controls incorporate system fault analysis for quick gas flow shut-off, coupled with automatic ignition retry upon sensing a fault correction. It is designed as a replacement for the following controls:

 

Goodman

 

White-Rodgers

 

 

 

 

0130F00005

PCBBF110

PCBBF123

50A55-743

0130F00005S

PCBBF110S

PCBBF123S

50A55-289

B1809926

PCBBF112

 

50T55-289

B1809926S

PCBBF112S

 

 

PRECAUTIONS

Installation should be done by a qualified heating and air conditioning contractor or licensed electrician.

If in doubt about whether your wiring is millivolt, line, or low voltage, have it inspected by a qualified heating and air conditioning contractor or licensed electrician.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and ordinances.

This control is a precision instrument, and should be handled carefully. Rough handling or distorting compo- nents could cause the control to malfunction.

Following installation or replacement, follow manufacturer’s recommended installation/service instructions to ensure proper operation.

!CAUTION

Do not short out terminals on gas valve or primary control. Short or incorrect wiring may damage the thermostat.

!WARNING

Failure to comply with the following warnings could result in personal injury or property damage.

FIRE HAZARD

Do not exceed the specified voltage.

Replace existing control with exact model and dash number.

Protect the control from direct contact with water

(dripping, spraying, rain, etc.).

If the control has been in direct contact with water, replace the control.

Label all wires before disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.

Route and secure wiring away from flame.

SHOCK HAZARD

Disconnect electric power before servicing.

Ensure proper earth grounding of appliance.

Ensure proper connection of line neutral and line hot wires.

EXPLOSION HAZARD

Shut off main gas to appliance until installation is complete.

www.white-rodgers.com

PART NO. 37-7348A

 

www.emersonclimate.com

1226

Page 1
Image 1
White Rodgers 50A55-743 installation instructions Installation Instructions, Description, Precautions