WIRING INSTRUCTIONS

WIRING INSTRUCTIONS

Standard electrical wiring of 120 volts, 60 Hz, 15 Amp circuit is adequate. Local residential and commercial wiring codes shall apply. Flexible conduit should be used (Fig. 5).

BOX (INTERNAL)

TOP OF

 

UNIT

 

GREEN

 

 

FIELD GROUND

WHITE

FIELD NEUTRAL

BLACK

FIELD HOT

FIG. 5 Electrical connection

OPERATION/MAINTENANCE

OPERATION

1.With the 120 VAC power turned on, adjust the knob to the position desired.

2.When the fan is running, the air cleaner will be operating. An arcing or “snapping” sound may be heard occasion- ally, however the unit is operating properly.

3.The Operating Light should be ON whenever the fan is running. An occasional flicker of the light accompanied by harmless sparking or snapping noise may occur. This is caused by the plates trapping large particles. If arcing is continuous, the cells should be washed or checked for service problems.

WASHING

! CAUTION

CABINET AND CELLS MAY CONTAIN

SHARP EDGES.

Use care when servicing unit or handling cells. Failure to do so could result in minor personal injury.

For maximum efficiency, your air cleaner cell and pre-filter should be inspected periodically and cleaned when neces- sary. The cleaning frequency will vary, depending on the amount of airborne contaminants. When cleaning is required the following procedure should be used:

CLEANING THE CELL

1.Turn the control switch to “OFF”.

2.Open the door, slide out charcoal filter, cell and pre-filter and re-close the door for safety. Replacement charcoal filters are available for odor control (see parts list).

NOTE: Do not wash the charcoal filter.

3.Using a solution of warm water and low sudsing detergent, soak cell for 20 to 30 minutes.

NOTE: Ionizing wires may become coated, causing loss of cleaning ability by the collecting cell. Using a damp cloth, wipe each ionizing wire, exercising care not to damage them.

4.Remove the cell from solution and rinse thoroughly with clean water. After removing cell, wash and rinse pre- filter.

5.Allow cell and pre-filter to drip dry for a minimum of

2 hours. Cell may be tipped at a slight angle to expedite the drip-dry process.

6.Open door and replace charcoal filter.

7.Slide cell into unit with air flow arrow pointing in direction of air flow.

8.Slide pre-filter screen into unit.

9.Close the door and securely fasten.

10.Turn the control switch to desired fan speed.

A moderate amount of arcing or “snapping” may occur at this time, which will indicate that the cell is still damp. If the noise is objectionable, turn the control switch to “OFF” and allow additional time for the cell to dry.