Clean | Clean |
Air Out | Air Out |
| Charcoal Filter |
| Reduces Odors |
| Collecting Plates attract |
| and hold dirt particles |
| like a magnet |
| Ionizing wires give dirt |
| particles a positive charge |
| Prefilter Screen |
DIRTY
AIR IN
FIG. 1 Illustration of Air Cleaning Process
INSTALLATION
PLACEMENT
The installer must be qualified to make approved electrical connections and a safe ceiling installation with attention to the best placement as shown in the following drawings.
The electronic air cleaner should be mounted on the ceiling near the center of the room. Air is drawn through the bottom of the air cleaner and discharged in four directions. Divide larger rooms into sections and use a unit in each section (see Fig. 2).
Mounting Detail
Be sure to select the mounting location so that the structure above is sufficiently strong to support the unit (approximately 70 lbs). See Fig.4.
CAUTION: Do not allow the unit to be supported by the ceiling tile grid suspension.
3/8 " DIA. STEEL
THREADED ROD | COVER |
WELD NUT |
|
FIG. 2 Divide large room into areas
Check existing air circulation in the room. The air cleaner should be installed so that it aids the circulation already established. When air flow patterns are not immediately apparent, observe the smoke from a cigarette in various locations within the room. Do not locate the air cleaner near a heating or air conditioning intake or exhaust vent if it interferes with the air flow discharge and return air to the heating or air conditioning unit.
CEILING MOUNT
The air cleaner is mounted to the ceiling. The mounting holes in the unit are spaced 16” and 261/2” between centers (Fig. 3).
ROOF SUPPORT JOIST | NUT & WASHER TOP AND BOTTOM |
ALTERNATE 2X4 | 2X4 |
|
|
| HANG THE AIR CLEANER | |||
MOUNTING METHOD |
|
|
|
|
| FROM THE TREADED STEEL | ||
|
|
|
|
|
|
| RODS TO TOP PLATE | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| FALSE |
|
|
|
|
| WELD NUTS | |
|
|
|
|
|
| |||
CEILINGS |
|
|
|
|
|
|
|
ALLOW AT LEAST 14" (356 mm)
FOR CELL REMOVAL
28
26 1/2 3/4
6
TOP
FRONT 16 28
6
**ALTERNATIVE: Wood 2 x 4's can be used at the False Ceiling Level and supported from above with 16 ga. wire min.
FIG. 4 Mounting details
FIG. 3 Installation Dimensions in Inches
3