White Rodgers T7350 Accessories, Infrared Thermostat Interface Module IR/TIM, Humidity Sensors

Models: T7351F T7350

1 24
Download 24 pages 60.15 Kb
Page 16
Image 16
Accessories

Accessories

Infrared Thermostat Interface Module (IR/TIM)

OS #: 50014064-001

Eliminates hard-to-find cables that connect a Palm® to the thermostat interface module.

T7350 thermostat programming can be done on the Palm and communicated via infrared to the I/R TIM, which automatically transmits it to the T7350. Simply download the T7350 program software at customer.honeywell.com onto the Palm. Once the T7350 is configured on the Palm, it can be beamed via the infrared port to the I/R TIM.

Most newer Palms are compatible.

Programs can be saved on the Palm and beamed again and again to other T7350s, saving time.

Users can capitalize on more T7350 features that are only accessible by using a Palm, including:

365-day holiday programming

Configurable ramp rates

Configurable PID loop tuning

Configurable standby setpoints

Configurable outdoor air temp lockout

Configurable high and low discharge air limits

Configurable dehumidification parameters

Remote Room Temperature and Discharge Air Sensors

Full line of remote wall sensors.

Gives user the option to have setpoint knobs/buttons, override button or sensor only.

Flush mount versions are available for high traffic areas where protruding objects would get broken.

TR21 — 20K Sensor only

TR21-A — 10K Averaging sensor

TR22 — 20K Sensor with setpoint knob

TR23 — 20K Sensor with setpoint knob and override button

T7770D1000 — 20K Sensor with override button

T7771A1005 — 20K or 10K Sensor with setpoint buttons and override button

C7772A1012 — 20K Flush mount sensor

C7041B2005 — 20K Discharge air sensor, 6" probe

C7041B2013 — 20K Discharge air sensor, 12" probe

Humidity Sensors

Available in wall- or duct-mount applications.

Allows for monitoring humidity via a wall sensor or within the return air duct

Available in different accuracies.

2%, 3% or 5% accuracy models for applications requiring different levels of accuracy.

H7625A1008 — 2% RH accuracy wall-mount humidity sensor with 20K room sensor

H7625B1006 — 2% RH accuracy duct-mount humidity sensor with 20K room sensor

H7635A1006 — 3% RH accuracy wall-mount humidity sensor with 20K room sensor

H7635B1004 — 3% RH accuracy duct-mount humidity sensor with 20K room sensor

H7655A1001 — 5% RH accuracy wall-mount humidity sensor

H7655B1009 — 5% RH accuracy duct-mount humidity sensor with 20K room sensor

16

Page 16
Image 16
White Rodgers T7350, T7351F manual Accessories, Infrared Thermostat Interface Module IR/TIM, Humidity Sensors