Appliance Operation

Plug the appliance mains electricity lead into a suitable supply and switch on the ON/OFF switch situated on the rear of the appliance. The ON/OFF switch is illuminated and will light up. The appliance should be positioned for easy access to the ON/OFF switch and mains plug to facilitate rapid switch off and appliance isolation when required.

For the T-2MA / T-2CA models Direct Water Supply mode. Please i) connect a hose to the water mains and to the unit, ii) turn the unit on. and iii) turn on your water mains.

The appliance may beep several times whilst internal components that may have moved during transportation reset themselves. If this does happen the beeping should last no longer than 20 seconds. If beeping continues for a longer period pull the Water Tank and the Ice Cube Drawer out slightly and re-insert them ensuring that they are fully home in their recesses. When the Water Tank is withdrawn the WATER TANK indicator on the Function Display should change color from green to red or red/orange, and when re- inserted it should go back to green. If the indicator stays red or red/orange this could indicate that the appliance internal water level detector is not operating correctly. Remove the Water Tank and check that the black float inside the transparent water level indicator on the right hand side of the rear of the Water Tank is free. If the float is stuck gently tap the indicator to free the float and the re-insert the Water Tank fully into its recess.

For the T-2MA / T-2CA models, in Direct Water Supply mode, users do not need to remove the water tank. The unit will automatically draw the water supply into the water tank. The unit will stop drawing water once the water tank is filled. At this point you may choose to shut off the water mains or leave it on. Once the water tank has been filled, you will be able to select your ice size and start the ice making cycle. If you have chosen to leave the water mains on, the unit will start to draw water into the tank again once it is empty. A low water level indicator float will be apparent if the water supply has been interrupted. Then the appliance may also be operated in manual mode.

Ice cube size S (small) of the SELECT display should be illuminated red as this is the default setting. If it isn’t depress the S button to illuminate it.

Press the START button on the Function Display and keep it pressed for a couple of seconds. The appliance will start with the water pump, cooling fan and compressor starting to operate. Looking through the right hand side of the clear Window in the top of the appliance water will be seen entering the water tray.

After approximately 12 minutes ice cubes will be deposited in the Ice Cube Drawer and the appliance will beep four times. Do not attempt to remove ice cubes until after the four beeps have finished otherwise the appliance will beep continuously and the cubes may be

Page 7
Image 7
Whynter T-2C/A, T-2M/A instruction manual

T-2C/A, T-2M/A specifications

The Whynter T-2M/A and T-2C/A are premium portable air conditioners designed to tackle the sweltering summer heat while providing excellent energy efficiency and user-friendly features. These units are perfect for those seeking comfort in both residential and commercial spaces.

Both models boast powerful yet efficient cooling capabilities, utilizing advanced technology to deliver a comfortable climate. The T-2M/A has a cooling capacity of 12,000 BTU, making it suitable for spaces up to 400 square feet, while the T-2C/A is designed similarly, offering effective cooling power for rooms of the same size. This impressive cooling capacity ensures that you can beat the heat even during the hottest days of summer.

One of the standout features of the Whynter T-2M/A and T-2C/A is their eco-friendly design. Both models utilize R-32 refrigerant, a more environmentally-friendly option that significantly reduces greenhouse gas emissions compared to traditional refrigerants. This technology not only helps the environment but also enhances energy efficiency, leading to lower electricity bills.

User convenience is also at the forefront of these models, with easy-to-use controls and a programmable timer that allows users to set cooling schedules to fit their lifestyles. Additionally, the units are equipped with remote controls, enabling users to adjust settings from a distance. The digital LED display provides clear visibility of the settings, ensuring hassle-free operation.

The dual hose system utilized by both the T-2M/A and T-2C/A enhances overall efficiency. This design allows for better air intake and exhaust, helping the unit to cool the room more effectively while minimizing the likelihood of air leakage. Furthermore, the portable nature of these units comes with sturdy caster wheels and a compact design, making it easy to move the air conditioners wherever they’re needed.

Both models also feature multiple fan speeds and modes, including dehumidification and ventilation modes, providing versatile climate control options for users. With a variety of air filtration methods, including washable pre-filters, they also contribute to improved air quality by trapping dust and allergens.

In conclusion, the Whynter T-2M/A and T-2C/A portable air conditioners embody a blend of performance, efficiency, and user-friendly features. These models are ideal for anyone looking to stay cool during hot weather while being conscious of energy consumption and environmental impact. Whether for home, office, or temporary living spaces, these portable units are an excellent investment in comfort and convenience.