D500 GT
Your Curtis ADS System is Factory Pre-Set for Optimum Performance.
After connection to water and power; the rear toggle switch must be on. You will hear a beep sound, indicating power is available to the controller.
The control displays
WILBUR CURTIS | . Press ON/OFF button and the screen will display |
|
<Airpot Brewer>
WILBUR CURTIS
After three seconds,
WILBUR CURTIS
FILLING
Water will fill the tank (approximately
Control will display | WILBUR CURTIS | when temperature reaches the setpoint (200°F). Unit is now ready to brew. |
READY TO BREW |
WILBUR CURTIS
HEATING
To Go Into Programming
Turn off (dark display) by pressing ON/OFF button (yellow). Press and hold BREW button (green) and then press and release ON/OFF button (yellow).
Continue holding BREW button. Display will read correspond to the buttons (see illustration below).
ENTERING PROGRAM MODE
ENTER CODE
– – – –
PROGRAM MENUS
< SELECT >
All programming selections are performed with the three center buttons. The symbols below the buttons are:
Scroll LEFT
SELECTION or ENTER to save new parameter
Scroll RIGHT
PROGRAM MENUS
During actual brew cycle a
for an increase of water volume.
Brew Volume (Factory set to 2.2 Liters)
Selecting Brew by Volume or Brew by Time depends on whether you know your brew time before starting. From Program Menus press > display will now show the next feature.
Brew by Volume: Press to Select, Display will now show Push START To Begin... Press the BREW button then hot water starts running, when desired volume is reached press BREW button again to stop the flow. Now the volume has been set. Pressing > button will display the subsequent menu features.
Next item in the sequence is Brew by Time. Press to Select to change the brew time. Display will now show the current time. By pressing < or > you can toggle back and forth from minutes to seconds to exit (ex). Change the time or set and exit by pressing .
Temperature (Factory set to 200°F) |
| |
Press | to Select. Press < or > to move to desired temperature and then | to set. Temperature is programmable from 170ºF to 204ºF in |
Energy Save Mode (Factory set to OFF) |
| |
Press | to Select, < or > ON, OFF or ON 140ºF , to set. When in ON, unit will automatically shut off 4 hours from last brew. When feature is OFF, unit does not have the energy saving mode. | |
In the ON 140ºF position, temperature goes down to 140ºF. if unit has not brewed in 4 hours.This feature will save energy by not heating the tank during periods of | ||
Brew Count Odom. |
| |
Press | to display total brew cycles. Press ex or Reset |
|
| ||
Press | to Select. Current setting in seconds is displayed < to decrease or select > to increase (range from OFF to 10 through 60 seconds), to set. | |
|
| |
| If | |
| dissappears from the list of program selections. |
|
|
|
|
Brew | Count Total |
|
Press | to Select, Shows total gallons and total brew cycles on the unit. Not resettable. | |
Cold Brew Lock . . . (Factory set to OFF) |
| |
Press | to select, < or > to select desired setting (CBL 5, 15 or OFF), | to set. |
The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point. The first setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF | |
is within 30 degrees of set point for the Ready to Brew message, however it will brew at any temperature. This feature will operate after initialization to set temperature after the rear standby toggle switch is | |
reset to ON. | |
Master | Reset |
Press | to display Are You Sure? |
Then | < for Yes, > for No. |
Brewer factory defaults are then reset. | |
Service Call (Phone number Factory set to [800] | |
Press | to display number and change number or < to move place and EX to exit when complete This number will be displayed during a Heating system SENSOR ERROR or during a WATER ERROR. |
Access Code (Factory set to | |
Press | to display number and change number, (the number can be change 1 to 4) or < to move place and ex to exit when complete. |
Banner Name (Factory set to WILBUR CURTIS) | |
Press | to display letters and change letters or < to move place and EX to exit when complete |
This feature allows up to 14 letters to be programmed for company name or regional name. Programming all blanks disables Banner Name. If programmed, Banner Name is displayed every 5 sec. on and off.
Press | to Select, Set gallons brewed to indicate |
Beeper On/Off (Factory set to ON) | |
Press | to display ON or OFF. Pressing either < or > toggles between on and off. to set. |
2 |
|