Williams 0743512, 0743511 For Your Safety Read Before Operating, Operating Instructions

Models: 0743511 0743512

1 12
Download 12 pages 36.51 Kb
Page 10
Image 10
 FOR YOUR SAFETY READ BEFORE OPERATING

Operating Instructions

Before operating the furnace, read carefully all warnings and safety information in this manual.

WHAT TO DO IF YOU SMELL FOR YOUR SAFETY READ BEFORE OPERATING  OPERATING INSTRUCTIONS

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

 

 

 

 

A. This appliance has a pilot which must be

Follow the gas supplier’s instructions.

lighted by means of the piezo igniter

- If you cannot reach your gas supplier, call the fire

installed on the unit. Do not try to light the

department.

pilot by hand.

C. Use only your hand to push in or turn the gas control

B. BEFORE LIGHTING smell all around the

knob. Never use tools. If the knob will not push in or turn

appliance area for gas. Be sure to smell

by hand, don’t try to repair it, call a qualified service

next to the floor because some gas is

technician. Force or attempted repair may result in a fire or

heavier than air and will settle on the floor.

explosion.

WHAT TO DO IF YOU SMELL

D. Do not use this appliance if any part has been under water.

GAS:

Immediately call a qualified service technician to inspect

- Do not try to light any appliance

the appliance and to replace any part of the control system

and any gas control which has been under water.

- Do not touch any electric switch; Do

 

 

not use any phone in your building

 

 

- Immediately call your gas supplier

 

 

from a neighbour’s phone.

 

 

TO TURN OFF GAS TO APPLIANCE OPERATING INSTRUCTIONS Manual background

1.STOP! Read the safety information above on this label.

2.Turn gas control knob clockwiseManual background to OFF. Do not force.

3.Wait (5) minutes to clear out any gas. If you then smell gas, STOP! Follow “B” in the safety information above on this label. If you don’t smell gas, go to the next step.

4.Turn gas knob counterclockwise Manual background to PILOT.

5.Look inside the flame view which is located on the external casing.

6.Push in control knob all the way and hold in. Immediately press the piezo igniter to end of the stroke, then release it. Continue pressing and releasing the piezo igniter with the control knob pressed down, until the pilot flame appears in the flame view. Once the pilot flame is lit, hold the control knob in for about one (1) minute.

7.Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 2. trough 6. .

-If knob does not pop up when released, stop and turn the gas tap installed on the gas supply line to the CLOSED position. Immediately call your service agency or gas supplier.

-If the pilot will not stay lit after several tries, turn the gas control knob to OFF and call your service technician or gas supplier.

8.Turn the control knob counterclockwise Manual background to the desired setting between HI and LO. The main burner flame will appear.

TO TURN OFF GAS TO APPLIANCE

1.Turn the control knob clockwise Manual background to OFF position. Do not try to switch from HI to OFF directly. Do not force.

2.Turn the gas tap installed on the gas supply to the CLOSED position.

9

Page 10
Image 10
Williams 0743512, 0743511 For Your Safety Read Before Operating, Operating Instructions, To Turn Off Gas To Appliance