Some Points to Remember

Some Points to Remember

Learn to recognize the odor of LP Gas. Your local LP Gas Dealer can give you a ”Scratch and Sniff” pamphlet. Use it to find out what the propane odor smells like. If you suspect that your LP Gas has a weak or abnormal odor, call your LP Gas Dealer.

If you are not qualified, do not light pilot lights, perform service, or make adjustments to furnaces on the LP Gas system. If you are qualified, consciously think about the odor of LP Gas prior to and while lighting pilot lights or performing service or making adjustments.

Sometimes a basement or a closed–up house has a musty smell that can cover up the LP Gas odor. Do not try to

light pilot lights, perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas.

Odor fade, due to oxidation by rust or absorption on walls of new cylinders and tanks, is possible. Therefore, people should be particularly alert and careful when new tanks or cylinders are placed in service. Odor fade can occur in new tanks or reinstalled old tanks if they are filled and allowed to set too long before refilling. Cylinders and tanks which have been out of service for a time may develop internal rust which will cause odor fade. If such conditions are suspected to exist, a periodic sniff test of the gas is advisable. If you have any question about the gas odor, call your LP Gas dealer. A periodic sniff test of the LP Gas is a good safety measure under any condition.

If, at any time, you do not smell the LP–Gas odorant, and you should, assume you have a leak. Then take

the same immediate action recommended above for the occasion when you do smell the odorized LP Gas.

If you experience a complete ”gas out” (the container is under no vapor pressure), turn the tank valve off immediately. If the container valve is left on, the container may draw in some air through openings such as pilot light orifices.

If this occurs, some new internal rusting could occur. If the valve is left open, then treat the container as a new tank. Always be sure your container is under vapor pressure by turning it off at the container before it goes completely empty or having it refilled before it is completely empty.

Technical Data

OUTPUT HEATING CAPACITY

kW

1.71

kBTU/hr

5,850

 

INPUT RATING

kW

2.17

kBTU/hr

7,400

 

MINIMUM INPUT RATING

kW

1.58

kBTU/hr

5,400

 

 

 

 

THERMAL EFFICENCY

%

79.05

LENGTH

mm

478

 

 

in

18-7/8”

 

HEIGHT

mm

577

in

22-3/4”

 

DEPTH

mm

173

 

 

in

6-3/4”

 

WEIGHT

kg

17/20

(OPERATING/SHIPPED)

lbs.

37/44

GAS CONNECTION

NPT

½”

MALE

 

 

WALL HOLE DIAMETER

mm

105

in

4-1/8”

 

 

 

 

AIR INLET DIAMETER

mm

100

in

3-7/8”

 

 

 

 

EXHAUST PIPE DIAMETER

mm

60

in

2-3/8”

 

MAX WALL THICKNESS

mm

495

in

19-1/2”

 

MIN WALL THICKNESS

mm

150

in

6

 

PRESSURE

MAX

 

MANIFOLD

MIN

 

 

MAX

GAS RATE

 

 

MIN

 

 

MINIMUM INLET

PRESSURE

NATURAL

mbar

8.7

GAS

in W.C.

3.5

LP

mbar

24.9

in W.C.

10.0

 

NATURAL

mbar

5.5

GAS

in W.C.

2.2

 

 

 

LP

mbar

14.4

in W.C.

5.8

 

NATURAL

m3/h

0.20

GAS

ft3/h

7.0

LP

m3/h

0.08

ft3/h

3.0

 

NATURAL

m3/h

0.14

GAS

ft3/h

5.1

 

m3/h

0.06

LP

ft3/h

2.2

 

NATURAL

mbar

17.4

GAS

in W.C.

7.0

 

 

 

LP

mbar

27.4

in W.C.

11.0

 

 

 

 

3

Page 4
Image 4
Williams 0743512, 0743511 installation instructions Some Points to Remember, Technical Data