High-Efficiency Direct-Vent Furnaces
Model Number
Natural | 0773512 | 1773512 | 2903512 |
Propane | 0773511 | 1773511 | 2903511 |
Btu/hr Input Rating | 7,400 | 17,700 | 29,000 |
Btu/hr Output Rating | 5,850 | 14,514 | 23,817 |
Efficiency Percentage |
|
|
|
Thermal | 79 | 82 | 82 |
Dimensions |
|
|
|
Width | 18⅞" | 21¾" | 39⅝" |
Depth | 6¾" | 8¼" | 8¼" |
Height | 22¾" | 28⅛" | 28⅛" |
Air Inlet Pipe Diameter | 3⅞" | 1⅞" | 1⅞" |
Exhaust Pipe Diameter | 2⅜" | 1⅜" | 1⅜" |
Noise Level at 10' may speed | 39 db | 41 db | |
Wall Hole Diameter | 4⅛" | 2" | 2" |
Electrical Supply | 110 Volts | 110 Volts | |
Air Flow (cfm) | 129 | 265 | |
Total Electrical Load | 86 | 140 | |
Maximum Wall Thickness | 19½" | 19⅝" | 19⅝" |
Type of Control | |||
Shipping Weight (lbs.) | 44 | 57 | 93 |
Gas connection: ½" · All models are rated for 2,000' elevation.
Accessories
Fragrance Holder Towel Warmer
| 17735 Series Accessories |
|
|
Umbrella Holder | Warming Tray |
|
|
Vent Adapter (17735 & 29035 Series)
The Vent Adapter Accessory is used to compensate for the extra space left around the vent hole when replacing a furnace with a larger vent opening. It can also be used to extend the flue terminal on homes with vinyl siding so that the vent cap lies flush against the edge of the siding.
Features
Unique
For clean, comfortable heat when and where you want it. The gas flame is completely sealed inside, away from all contact with room air. Air necessary for combustion is drawn into the chamber from outside through direct wall vent, and all combustion products are vented directly to the outside. Only clean, gentle heat, in continuous circulation is delivered into the room. Windows and doors can stay closed because no room air is used for combustion.
17735 and 29035 Series
Humidification System
Relieve the effects of dry winter air.
Programmable Timer
A programmable thermostat in your home is one of the easiest ways to save energy and money. On/off,
Summertime Ventilation
A
Air Filter
Easy access, keeps the fans clean and is low maintenance.
Termination Cap (Flue)
Small,
| 29035 Series |
|
|
|
|
|
07735 Series |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| Important |
|
| |
No electricity required |
|
| · Read owner's manual before using/installing. |
|
| |
|
|
| · Photographs are representative. |
|
| |
|
|
| · Check local codes and ordinances for permitted uses. |
|
| |
|
|
| · Consult installation manual for clearances prior to installation. |
|
| |
250 West Laurel Street · Colton, California 92324 USA |
| · We reserve to right to amend product specifications without notice. |
|
| ||
| · Installation and servicing recommended by a qualified service person. |
|
| |||
(909) |
|
|
| |||
| · Venting must comply with the installation manual. |
|
| |||
Consumer Line: (888) |
|
|
| |||
| · Please read the warranty for any limitations for disclaimers. |
|
| |||
Homeowner Assistance: (909) |
|
|
| |||
| · Combustion chamber carries a |
| ||||
|
|
| ||||
|
|
|
|
|
| |
|
|
|
|
|
|
|
© 2009 Williams Furnace Co. | Printed in U.S.A. | All Rights Reserved | Subject to Change without Notice | L1457 |