TROUBLESHOOTING

 

 

 

PROBLEM.

CAUSE

SOLUTION

 

 

 

 

 

 

Little or no solution flow

 

Clogged spray jet on cleaning

Remove and clean jets

 

 

tool

 

 

 

 

 

 

 

Faulty pump

Check and replace pump.

 

 

 

(Call Windsor Tech. Services first)

 

 

 

 

 

 

 

Incorrectly attached solution

Ensure solution hose coupler is securely attached to the

 

 

 

hose

coupler on the solution tank.

 

Loss of vacuum/

 

Incorrectly attached vac hose

Ensure vac hose is pushed completely onto the recovery

 

Solution recovery

 

tank inlet.

 

 

 

 

 

 

Obstruction in cleaning tool

Inspect for and remove any debris.

 

 

 

Recovery tank is not securely

Tighten latch on back end of the machine.

 

 

 

mounted on the solution tank.

 

 

 

 

 

WIRING DIAGRAM