| TROUBLESHOOTING/WIRING DIAGRAM | ||
TROUBLESHOOTING |
|
|
| |
PROBLEM. | CAUSE | SOLUTION |
| |
|
|
|
|
|
Little or no solution flow |
| Clogged spray jet on cleaning | Remove and clean jets |
|
| tool |
| ||
|
|
|
| |
|
| Faulty pump | Check and replace pump. |
|
|
| (Call Windsor Tech. Services first) |
| |
|
|
|
| |
|
| Incorrectly attached solution | Ensure solution hose coupler is securely attached to the |
|
|
| hose | coupler on the solution tank. |
|
Loss of vacuum/ |
| Incorrectly attached vac hose | Ensure vac hose is pushed completely onto the recovery |
|
Solution recovery |
| tank inlet. |
| |
|
|
| ||
|
| Obstruction in cleaning tool | Inspect for and remove any debris. |
|
|
| Recovery tank is not securely | Tighten latch on back end of the machine. |
|
|
| mounted on the solution tank. |
| |
|
|
|
|
WIRING DIAGRAM
PRSIF2/PRSDIF2 98902 02/08/03 | |
|