MACHINE TROUBLESHOOTING

PROBLEM

CAUSE

SOLUTION

Poor or no water pick-up

Squeegee out of

Adjust squeegee

on either squeegee

adjustment

 

 

Debris caught on

Remove debris

 

squeegee

 

 

Worn squeegee blades

Rotate or replace squeegee

 

 

blades

 

Vacuum hose clogged

Clear obstruction from hose

 

 

 

 

Vacuum hose

Reconnect vacuum hose

 

disconnected from

 

 

squeegee or recovery tank

 

 

Vacuum hose damaged

Replace vacuum hose

 

Recovery tank not sealed

Place recovery tank dome on

 

 

tank. Replace damaged

 

 

gaskets.

 

Foam filling recovery tank

Empty recovery tank

 

 

Use less or different detergent

 

 

Use defoamer

Vacuum motor does not run, or

Recovery tank full

Drain recovery tank

runs slowly

 

 

 

Recovery tank float system

Clean float system

 

dirty

 

 

Circuit breaker tripped

Reset circuit breaker

 

Loose connection

Check motor wires and

 

 

connections

 

Faulty vacuum switch

Replace switch

 

Worn vacuum motor

Replace brushes, check

 

brushes

commutator

Poor scrubbing performance

Debris caught in scrub

Remove debris

 

brushes

 

 

Worn brushes or pads

Replace brushes or pads

 

Improper detergent, brush

Contact equipment or

 

or pad used

application specialist

 

Low scrub brush down

Increase brush pressure

 

pressure

 

 

Low battery charge

Charge batteries

Brush motors do not run, or runs

Circuit breaker(s) tripped

Reset circuit breaker(s)

slowly

 

 

 

Loose connection

Check motor wires and

 

 

connection

 

Faulty brush motor

Replace contactor

 

contactor

 

 

Worn brush motor brushes

Replace brushes, check

 

 

commutator