Winegard RMDM04 Digital Elevation Sensor Roof Connections, Inside RV, Supplied with DM-2000 only

Models: RMFLDM4 RM-DM46 RMDM04 RM-DM00

1 11
Download 11 pages 27.47 Kb
Page 4
Image 4
Digital Elevation Sensor Roof Connections

STEP 3. Attach dish to backup. Use bolts and nuts provided. See Figure 4.

STEP 4. Mount dish on roof in upright position. Rotate clockwise to stop (Figure 5). Dish will be toward back of vehicle when in stowed or travel position. The word FRONT is embossed on the base and should face the front of vehicle. Secure to roof using screws (provided). The travel bracket should be mounted to roof 6-1/8” from base of dish, toward back of vehicle. See Figure 6.

NOTE: Apply non-hardening sealing compound to screw heads, coax access hole and edge of gasket under mount base.

Figure 4

(4)Antenna Mounting Bolts

(4)1/4-20 Hex Nuts

Digital Elevation Sensor Roof Connections

The illustrations below show the different methods of connecting wires at roof level; method will depend on model. Wire colors must match, i.e. red to red, green to green, black to black.

This wire harness connects to the digital

Supplied with DM-2000 only

 

3M UR TERMINAL

 

elevation sensor on the antenna.

Squeeze pliers until

DO NOT STRIP

 

 

red plunger is flush

Snap

wires. Terminal

with rest of terminal.

connectors

is self-stripping.

(Pliers not supplied.)

together

Slide wires all the way in.

 

 

 

 

NOTE: This terminal is weatherproof

 

NOTE: This terminal is NOT WEATHERPROOF

and can be left outside on the roof IF

 

SECURED PROPERLY to prevent wind

 

and CANNOT be left outside on the roof.

 

whipping.

 

Install the vent tube on the back of the mount base (the side opposite the word FRONT). The hole for the vent tube is shown in Figure 6A. CAUTION: DO NOT seal hole in vent tube. Put sealant around the outside of the vent tube, approximately 1/2” from end. Push vent tube into the hole. The sealant will seal the hole as you push in vent tube. Leave approximately 2 to 2-1/2” of the vent

Figure 5

Rotate

Inside RV

For roof thickness greater than 6-1/2”. Parts Needed: (not included)

14” worm gear for roof

Directional handle extensionFigure 8 Long threaded rod

Figure 10

Roof

Directional

Threaded

Worm Gear

Handle Length

Rod

Shaft Length

Thickness

(Figure 9)

Length

(Figure 11)

 

 

 

 

 

tube extending from the hole. Put a small amount of sealant on the roof under the vent tube end to hold in place.

Measure 24” of coax at plastic fastener on left side of feed arm. Supplied with DM-2000 only

clockwise to stop.

Instructions:

Threaded Rod, Washer and Nut

1-1/2”

2-7/8”

2-3/4”

2-7/8”

1-3/4”

3-1/4”

3”

3-1/8”

2”

3-1/2”

3-1/4”

3-1/2”

Figure 6

Base Plate

(See Step 5.)

No cable clamps on this part of cable.Inside RV

Install cable entry plate 3” minimum from mount base.

STEP 8. Place nut on threaded rod. See Figure 8.

STEP 9. Measure and cut the threaded rod with a For roof thickness greater than 6-1/2”. Parts Needed: (not included)Instructions:Figure 6Adoes not. hacksaw. Use the chart (Figure 10) to determine the correct length.

STEP 10. Remove the nut over the cut end of the threaded rod. This cleans the threads after cutting.

STEP 11. Thread the cut end of the rod into the hub.

2-1/4”

3-7/8

3-1/2”

3-7/8”

2-1/2”

4-1/8”

3-3/4”

4-1/8”

2-3/4”

4-1/2”

4”

4-1/2”

3”

4-3/4”

4-1/4”

4-3/4”

3-1/4”

5”

4-5/8”

4-7/8”

3-1/2”

5-1/4”

4-7/8”

5-1/8”

3-3/4”

5-5/8”

5-1/4”

5-1/2”

4”

5-3/4”

5-1/2”

5-3/4”

4-1/4”

6-1/8”

5-3/4”

6-1/8”

4-1/2”

6-1/2”

6”

6-1/4”

Figure 6A

CAUTION: DO NOT GET sealing compound between base plate and rotating gear housing. DO NOT PAINT top of base plate or around rotating gear housing.

STEP 5. Facing the front of the dish, note the coax attached to the side of the feed arm. Measure 24” coax from this point. DO NOT CUT. Put coax around mount base, Figure 5.

Another Method of Installing Roof/Cable Entry Plate Attach cable to roof using cable clamps. Use sealant to seal screw heads.

STEP 12. Install the ceiling plate. The rotate/lock lever must point toward the rear of the vehicle.

Be sure rotate/lock lever is pointing towards the rear of the vehicle and that the hole in ceiling plate aligns with hole in the ceiling.

Refer to the chart to determine the correct length for the directional handle. Extensions may be needed. Each extension adds 2-1/4” to directional handle. DO NOT cut the extension. If the directional handle must be extended by less than 2-1/4”, cut the directional handle to fit.

A tube cutter is recommended for cutting the directional handle. This gives a square cut; a hacksaw

4-3/4”

6-5/8”

6-1/8”

6-3/8”

5”

6-7/8”

6-3/8”

6-5/8”

5-1/4”

7-1/8”

6-5/8”

7”

5-1/2”

7-3/8”

6-7/8”

7-1/4”

5-3/4”

7-5/8”

7-1/4”

7-1/2”

6”

7-7/8”

7-1/2”

7-3/4”

6-1/4”

8-1/8”

7”

8”

6-1/2”

8-1/2”

7-3/4”

8-1/4”

6 3/4”

8 3/4”

8”

8

1/2”

7”

9”

8 1/4”

8

7/8”

7-1/4”

9-3/8”

8 5/8”

9

1/8

7-1/2”

9-5/8”

8 7/8”

9

3/8

7-3/4”

9-7/8”

9 1/8”

9

5/8

STEP 6. Apply approved sealing compound over mounting screw heads in base plate.

STEP 7. Feed coax through the roof using cable entry plate (included). See Figure 7. Weatherproof the cable entry by applying sealant under lip of cable entry plate and where cable enters roof. Attach plate to roof with screws provided. Apply sealant over screws and around edge of roof-thru plate, making sure cable entry is sealed. If downlead connection is made on top of roof, make sure to weatherproof connection!

Figure 7

#10 x 1” Screws

Down lead connects to satellite receiver

Cable Entry Plate HANDLE CE-2000

Down lead

FS-8100

Male-to-male

F-connector

does not.

Be sure large and small keyways line up in the hub and directional handle!

Figure 9

 

 

 

 

 

 

 

 

 

 

 

DIRECTIONAL

 

 

 

 

 

HANDLE

 

HANDLE

 

LENGTH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8”

10-1/8”

9 3/8”

10

8-1/4”

10-3/8”

9 5/8”

10 1/4

8-1/2”

10-3/4”

9 7/8”

10 3/8

8-3/4”

11”

10”

10 5/8

9”

11-1/4”

10-1/4”

11

9-1/4”

11-1/2”

10-5/8”

11 1/4

9-1/2”

11-3/4”

10 7/8”

11 1/2

9-3/4”

12”

11 1/8”

11 3/4

10”

12-3/8”

11 3/8”

12

10-1/4”

12-5/8”

11 5/8”

12 1/4

10-1/2”

12-7/8”

11 7/8”

12 1/2

5

6

Page 4
Image 4
Winegard RMDM04 Digital Elevation Sensor Roof Connections, Inside RV, Supplied with DM-2000 only, Instructions, A, Handle