Installation Notes

The Wolf outdoor gas grill is designed for

easy placement into a built-in enclosure.Be

sure to maintain the minimum clearances

shown in the illustrations.

Complete installation specifications can be

found on our website, wolfappliance.com.

Model BBQ36C shown.
Unit dimensions may vary by ±
1
/
8
".

Specifications

Exterior Finish Classic Stainless Steel

Overall Width 36"

Overall Height

(BI) Models 26"

(C) Models 523/4"

Overall Depth 30"

Combustible Enclosure

Opening Width 381/4"

Opening Depth 273/4"

Non-Combustible Enclosure

Opening Width 361/4"

Opening Depth 263/4"

Electrical Requirements 110/120V AC

60 Hz, 15 amp circuit

Power Cord 9' cord with grounded plug

Shipping Weight 340–460 lbs

Installation Specifications—Built-In (BI) Models

Combustible Enclosure

Overall Dimensions

36" Outdoor Gas Grill
Dimensions in parentheses are in
millimeters unless otherwise specified.
361/4" (921)
TO GRILLINGSURFACE
523/4"
(1340)OVERALL
HEIGHT
263/4"
(680)
HEIGHT
OF CART
26"
(660)
HEIGHT
OF GRILL
36" (914)
OVERALL WIDTH
6"
(152)
255/8" (651)
30" (762)
OVERALL DEPTH
303/8" (771) WITH HOOD OPEN
561/2"
(1435)
HEIGHT
WITHHOODOPEN

Non-Combustible Enclosure

361/2"max
(927)
381/4" (972)
ROUGH OPENING WIDTH
COMBUSTIBLE ENCLOSURE
273/4" (705)
ROUGH OPENING
DEPTH
101/2" (267)
ROUGH
OPENING
HEIGHT
18"
(457) min 18"
(457) min
18"
(457) min
101/2" (267)
ROUGH
OPENING
HEIGHT
31/8"
(79)
31/8"
(79)
33/4" (95)
2" (51) DIAMETER OPENING
FOR GAS SUPPLY CONNECTION
(BACK WALL LOCATION OR
BOTTOM LOCATION)
ALLOW OPENING
FOR ACCESS
DOOR
LOCATE
ELECTRICAL
OUTLET FOR
ROTISSERIE
ON LEFT SIDE
2" (51) DIAMETER OPENING
FOR GAS SUPPLY CONNECTION
(BOTTOM LOCATION)
27/8"
(73)
E
C
L
C
L
NOTE: Dimensions include insulated liner.
361/2"max
(927)
NON-COMBUSTIBLE ENCLOSURE
263/4" (680)
ROUGH OPENING
DEPTH
91/2" (242)
ROUGH
OPENING HEIGHT
6"
(152)
min
6"
(152)
min
3"
(76)
min
91/2" (242)
ROUGH
OPENING HEIGHT
21/8"
(54)
21/8"
(54)
23/4"
(70)
LOCATE
ELECTRICAL
OUTLET FOR
ROTISSERIE
ON LEFT SIDE 17/8"
(48)
E 361/4" (921)
ROUGH OPENING WIDTH
2" (51) DIAMETER OPENING
FOR GAS SUPPLY CONNECTION
(BACK WALL LOCATION OR
BOTTOM LOCATION)
ALLOW OPENING
FOR ACCESS
DOOR
2" (51) DIAMETER OPENING
FOR GAS SUPPLY CONNECTION
(BOTTOM LOCATION)
C
L
C
L