Installation Notes
The Wolf outdoor gas grill is designed for
easy placement into a built-in enclosure.Be
sure to maintain the minimum clearances
shown in the illustrations.
Complete installation specifications can be
found on our website, wolfappliance.com.
Model BBQ36C shown.
Unit dimensions may vary by ±
1
/
8
".
Specifications
Exterior Finish Classic Stainless Steel
Overall Width 36"
Overall Height
(BI) Models 26"
(C) Models 523/4"
Overall Depth 30"
Combustible Enclosure
Opening Width 381/4"
Opening Depth 273/4"
Non-Combustible Enclosure
Opening Width 361/4"
Opening Depth 263/4"
Electrical Requirements 110/120V AC
60 Hz, 15 amp circuit
Power Cord 9' cord with grounded plug
Shipping Weight 340–460 lbs
Installation Specifications—Built-In (BI) Models
Combustible Enclosure
Overall Dimensions
36" Outdoor Gas GrillDimensions in parentheses are in
millimeters unless otherwise specified.
361/4" (921)
TO GRILLINGSURFACE523/4"
(1340)OVERALLHEIGHT
263/4"
(680)HEIGHT
OF CART26"
(660)HEIGHT
OF GRILL36" (914)
OVERALL WIDTH6"
(152)255/8" (651)
30" (762)
OVERALL DEPTH303/8" (771) WITH HOOD OPEN
561/2"
(1435)HEIGHT
WITHHOODOPENNon-Combustible Enclosure
361/2"max
(927)
381/4" (972) ROUGH OPENING WIDTH
COMBUSTIBLE ENCLOSURE
273/4" (705) ROUGH OPENING
DEPTH
101/2" (267) ROUGH
OPENING
HEIGHT
18" (457) min 18"
(457) min
18" (457) min
101/2" (267) ROUGH
OPENING
HEIGHT
31/8" (79)
31/8" (79)
33/4" (95) 2" (51) DIAMETER OPENING
FOR GAS SUPPLY CONNECTION
(BACK WALL LOCATION OR
BOTTOM LOCATION)
ALLOW OPENING
FOR ACCESS
DOOR
LOCATE
ELECTRICAL
OUTLET FOR
ROTISSERIE
ON LEFT SIDE
2" (51) DIAMETER OPENING
FOR GAS SUPPLY CONNECTION
(BOTTOM LOCATION)
27/8" (73)
E C
L
C
L
NOTE: Dimensions include insulated liner. 361/2"max
(927)
NON-COMBUSTIBLE ENCLOSURE
263/4" (680) ROUGH OPENING
DEPTH
91/2" (242) ROUGH
OPENING HEIGHT
6" (152)
min
6" (152)
min
3" (76)
min
91/2" (242) ROUGH
OPENING HEIGHT
21/8" (54)
21/8" (54)
23/4" (70)
LOCATE
ELECTRICAL
OUTLET FOR
ROTISSERIE
ON LEFT SIDE 17/8"
(48)
E 361/4" (921) ROUGH OPENING WIDTH
2" (51) DIAMETER OPENING
FOR GAS SUPPLY CONNECTION
(BACK WALL LOCATION OR
BOTTOM LOCATION)
ALLOW OPENING
FOR ACCESS
DOOR
2" (51) DIAMETER OPENING
FOR GAS SUPPLY CONNECTION
(BOTTOM LOCATION)
C
L
C
L