Pro Wall Hood Installation

21

In-Line and Remote Blowers

BLOWER INSTALLATION

IMPORTANT NOTE: Refer to specific installation instruc- tions provided with each blower assembly for additional mounting and wiring instructions.

IMPORTANT NOTE: Use wire connectors or wire nuts approved by UL or C/UL.

Follow specific wiring instructions provided with each blower. Black (L1) to black, white (neutral) to white, or white to blue, or white to brown (depending on model) and green to grounding screw. Run ROMEX cable to the hood.

Insert 6" (152) of ROMEX cable through the knockout opening and into the electrical box on the back plate of the hood. Secure the cable to the electrical box with an appropriate connector.

Locate the cord assembly provided with the blower. The cord assembly has two leads, black (L1) and white (neutral). Connect these leads to the leads from the blower, black to black and white to white.

Connect all green and bare wires together to the ground screw in the electrical box.

wolfappliance.com/specs

Plug the cord assembly into the receptacle located near the center of the hood shell. Refer to the illustra- tion below. Use the clips on the interior of the hood to secure excess power cord.

Reinstall the electrical box cover and screws in the upper right-hand corner of the hood. Make sure all wires are secure and that no wires are pinched between the cover and box.

IMPORTANT NOTE: Before turning the power on to the ventilation hood, make sure the blower is off.

When making electrical connections, make sure the electrical power is turned off at the power source or circuit breaker before proceeding.