Planning Information

Pro Ventilation Hood Liner

M O D E L P L 4 6 2 2 1 2

D U C T I N G C O N S I D E R A T I O N S

Wolf Pro hood liners are shipped without the blower assembly. Internal, in-line and remote blower assemblies are available.

IMPORTANT NOTE: Install this ventilation hood liner only with a Wolf blower.

Pro hood liners have a vertical discharge location with 10" (254) round duct. A transition with backdraft damper is included. The hood liner will operate most efficiently when ductwork does not exceed 50' (15 m) in length.

Local building codes may require the use of make-up air. Consult your local HVAC profes- sional for specific requirements in your area.

IMPORTANT NOTE: Wolf Pro hood liners must be vented to the outside. Use only metal ductwork.

Refer to the illustration below for ducting considerations for Pro ventilation hood liners.

DUCTWORK INSTALLATION

THROUGH ROOF

ROOF CAP OR REMOTE BLOWER

10" ROUND DUCT

 

TRANSITION

SOFFIT OR CABINET

221/4"W x 9"D

TO 10" ROUND 10"H

OR DUCT COVER

DIMENSIONS INCLUDE FLANGES

DECORATIVE HOOD

 

 

VERTICAL DISCHARGE

12" (305)

HOOD LINER

HEIGHT OF LINER

 

221/2" (572)

DEPTH OF LINER

30" TO 36"

(762–914)

COUNTERTOP

TO BOTTOM OF

DECORATIVE HOOD

Ducting for Pro ventilation hood liners.

36" (914)

STANDARD

FLOOR TO

COUNTERTOP

HEIGHT

VERTICAL DISCHARGE ONLY FOR VENTILATION HOOD LINERS.

Dimensions in parentheses are in

millimeters unless otherwise specified.

6

Page 6
Image 6
Wolf Appliance Company PL462212 dimensions C T I N G C O N S I D E R a T I O N S