Planning Information

Pro Ventilation Hood Liner

M O D E L P L 4 6 2 2 1 2

W O L F B L O W E R A S S E M B L I E S

A ventilation system must include a blower assembly. Wolf ventilation hood liners are shipped without the blower assembly. An internal, in-line or remote blower assembly must be selected to accommodate the cooking appli- ance, CFM requirements and homeowner prefer- ences. Internal, in-line and remote blower assem- blies are available as sales accessories through your Wolf dealer.

IMPORTANT NOTE: Use only a Wolf blower with all Wolf ventilation products.

 

 

247/8"

 

 

(632)

18"

12"

 

(457)

 

 

(305)

 

 

 

8"

 

 

(203)

 

22"

18"

 

(559)

(457)

Internal blowers are mounted inside the hood liner canopy. In-line blowers are mounted in between the hood liner and the exterior of the home. Remote blowers can be mounted on the roof or in some cases, on an exterior wall. Refer to the illustrations below for dimensions of Wolf in-line and remote blowers.

Pro ventilation recommendation charts on the following page provide minimum CFM recom- mendations according to the cooking appliance and hood liner used and blower options for each specific Pro hood liner.

In-line BLOWER-110IL

 

 

203/4"

281/4"

 

(527)

 

 

(718)

10" (254)

 

 

 

 

Diameter

 

151/2"

 

241/2"

(394)

 

 

 

(622)

 

14"

 

 

(356)

 

 

243/4"

43/4"

 

(121)

 

(629)

 

Remote BLOWER-90REM

 

18" (457)

 

10"

291/2"

(254)

(749)

 

10" (254)

 

Diameter

 

143/4"

1

(375)

29 /2"

(749)

 

101/8"

 

(257)

 

22"

71/4"

(559)

(184)

Remote BLOWER-120REM

 

21" (533)

 

10"

291/2"

(254)

 

(749)

 

10" (254)

 

Diameter

 

143/4"

291/2"

(375)

 

(749)

103/8"

 

(264)

 

25"

71/4"

(635)

(184)

Remote BLOWER-150REM

Unit dimensions may vary by ± 1/8" (3).

Dimensions in parentheses are in

 

millimeters unless otherwise specified.

7

Page 7
Image 7
Wolf Appliance Company PL462212 dimensions L F B L O W E R a S S E M B L I E S