-3-
W1760 20-Gallon Parts Washer
POWER SUPPLY. This machine requires a grounded
110V power supply circuit that is rated for a 15A.
PREVENTING ELECTRICAL SHOCK. Only connect this
parts washer to a properly grounded GFCI (Ground
Fault Circuit Interrupt) receptacle. Test the GFCI
receptacle operation according to switch manufac-
turer recommended intervals.
GROUND PRONG. Never cut off the ground prong
from the power cord in order to plug the parts wash-
er power cord into an non-grounded wall receptacle
or extension cord.
PREVENTING FIRE. Do not fill this parts washer with
gasoline, kerosene, fuel, or flammable solvents. Do
not disconnect or modify the automatic lid closure
device in any way. Keep an appropriate class fire
extinguisher close at hand.
SAFE USAGE. Never smoke, use a drop light, or any
other hand-held ignition source or electrical device
near the parts washer. An ignition source or electri-
cal device that falls into the cleaning solution can
cause severe burns or electrocution.
PERSONAL PROTECTION. To prevent personal con-
tamination, always wear gloves, goggles, an apron,
and a respirator when using or changing the parts
washer liquid. Wash your hands with soap and water
after every use.
LOCATION. Make sure that the parts washer is locat-
ed in an area with adequate ventilation to prevent a
buildup of vapors, and always keep the parts washer
away from all sources of ignition.
SAFE STORAGE. Keep away from children and ani-
mals. Close the lid when not using the parts washer.
MAINTENANCE. Clean or replace tank filter before
it becomes clogged, and inspect for leaks. Follow
OSHA, EPA, and the manufacturer's solution replace-
ment schedules and disposal regulations.
USE this parts washer with caution and
respect. Always consider safety first,
as it applies to your individual working
conditions. No list of safety guidelines
can be complete—every shop environ-
ment is different. Failure to follow
safety guidelines could result in serious
personal injury or death.
This parts washer is designed to store
cleaning solutions. During storage some
liquids can grow dangerous microbes,
or due to the collection of toxic metal
and contaminants from the items being
washed, the fluid can become a very
poisonous solution to humans and
animals.
USE the correct personal protection
equipment when handling sharp
workpieces to prevent cuts, infections,
and poisoning.
FOLLOW OSHA, EPA, and the fluid
manufacturer's requirements to
properly dispose of cleaning liquids
when it becomes time to change the
liquid.
BIOLOGICAL and POISON
HAZARD!
Operating Voltage Amp Draw Min. Circuit Size Plug/Recommended Plug Extension Cord
110V Operation 0.7 Amps 15A, GFCI NEMA 5-15 16 Gauge