| Model PA1235X | Page 13 |
|
|
|
|
|
| SPECIFICATIONS |
|
|
|
|
|
|
| Number of channels | 12 |
|
|
|
|
|
| Power Output | 35 Watts at 8 Ohms |
|
| Rated continuous power, each channel, all 12 channels |
|
|
| simultaneously driven, 20 Hz to 20kHz, at rated THD |
|
|
|
|
|
|
| Power Output | 55 Watts at 8 Ohms |
|
| Short term continuous, each channel, 2 channels driven, | 80 Watts at 4 Ohms |
|
| 1 kHz, at rated THD |
|
|
|
|
|
|
| Bridged Power Output | 150 Watts at 8 Ohms (80 Watts continuous) |
|
| Short term continuous, one pair driven at 1 kHz, at rated THD |
|
|
|
|
|
|
| Rated THD | < 0.08% |
|
|
|
|
|
| Damping Factor | > 100 |
|
| at 50 Hz, half rated power |
|
|
|
|
|
|
| S/N Ratio | > 100 dB |
|
|
|
| |
|
|
|
|
| Frequency Response | 12 Hz to 55 kHz |
|
| at 1 Watt, ± 3dB |
|
|
|
|
|
|
| Input Sensitivity | Max: 0.5 V |
|
| at rated power, stereo mode | Default: 1.0 V |
|
|
| Minimum: Off |
|
|
|
|
|
| Input Impedance | Local Inputs: 22 kOhms |
|
|
|
|
|
| Power Source | 120 VAC, 60 Hz |
|
|
| 240 VAC, 50 Hz (European version) |
|
|
|
|
|
| Power Consumption | No signal: 30 Watts (0.25/0.13 A) |
|
|
| 12 Channels at 1/10 rated power: 360 Watts (3.0/1.5 A) |
|
|
| 12 Channels at rated power: 1044 Watts (9.1/4.6 A) |
|
|
| 6 Channels Bridged at 8.5 Watts/Chan: 720 Watts (6.0/3.0 A) |
|
|
|
|
|
| Remote On/Off and | +5 V to +30 VDC (16 mA at +12 VDC) |
|
| CI Voltage/Current |
|
|
|
|
|
|
| Line Fuse Rating | 120 V version: 10 A Slow Blow 220 VAC. |
|
|
| TMRA 30° Celsius. If this temperature is exceeded, you will |
|
|
| need to provide additional ventilation to insure proper |
|
|
| operation. |
|
|
| 240 V version: 5 A |
|
|
|
|
|
| Dimensions | 19” W x 5.25” H x 15.5” D |
|
|
| (483 mm W x 133 mm H x 394 mm D) |
|
|
|
|
|
| Weight | 36.85 lbs (16.7 kg) |
|
|
|
|
|
© 2002 Xantech Corporation.