A Specifications

Specifications are subject to change without notice.

Mechanical Specifications

Physical Specifications

XADC-40

XADC-60

XADC-80

 

 

 

 

Weight

7.9 lb

8.2 lb

8.3 lb

 

(3.6 kg)

(3.7 kg)

(3.8 kg)

 

 

 

 

Operating temperature range

14 ºF – 86 ºF (-10 ºC – 30 ºC)

 

de-rated 86 ºF – 140ºF (30 ºC – 60 ºC)

 

> 140ºF (60 ºC) unit may shut down

 

 

Length

11 13/16 in. (300.0 mm)

 

 

Width

7 1/8 in. (180.0 mm)

 

 

Height

4 3/4 in. (120.0 mm)

 

 

 

 

Electrical Performance

 

 

 

 

AC Input

XADC-40

 

XADC-60

 

XADC-80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input current (at rated output)

 

6 Aac

 

9 Aac

 

12 Aac

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal input voltage

 

 

120 Vac, 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal operating input voltage

 

108 Vac – 130 Vac

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min. operating input voltage

 

 

 

90 Vac

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. operating input voltage

 

 

 

140 Vac

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power factor (rated output, nominal input)

 

 

 

≥ 0.95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Safe (non-operating) input voltage range

 

 

0 – 150 Vrms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency

 

 

 

50 – 70 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 