Xantrex Technology 40 A (XADC-40), 60 A (XADC-60) manual Switching the XADC On and Off, Maintenance

Models: 80 A (XADC-80) 60 A (XADC-60) 40 A (XADC-40)

1 20
Download 20 pages 61.29 Kb
Page 15
Image 15
2 Operation and Troubleshooting

Towable-OEM-40-60-80A.book Page 5 Monday, March 5, 2007 12:15 PM

2 Operation and Troubleshooting

Switching the XADC On and Off

The XADC is always On when AC voltage is applied. To switch the XADC Off, disconnect the AC input voltage by turning the AC breaker off.

Maintenance

It may be necessary to replace the DC fuses in the XADC. Fuses for XADC should be:

XADC-40

XADC-60

XADC-80

2 × 30 Aa

3 × 30 Aa

4 × 30 Aa

a.Littelfuse Type 257 or equivalent

If the optional AC/DC Distribution Panel is installed, it may be necessary to replace the AC breakers and DC fuses.

Fuses for DC loads should be:

Littelfuse Type 257 or equivalent and the maximum allowed fuse for the DC loads is 20 A.

Breakers for the AC side should be:

MAIN: Cutler Hammer/Bryant/Westinghouse Type BR Series and ITE Gould QP Series. The maximum current rating for the main breaker is not to exceed the rating of the panelboard.

BRANCH: Cutler Hammer/Bryant/Westinghouse Type BR, BD Series and ITE Gould QP, QT Series. The maximum current rating for the branch breaker is not to exceed 20A.