Specification
OUTPUT
Voltage Range: | 0V to 42V minimum |
Current Range: | 0A to 10A minimum |
Output Voltage Setting: | By coarse and fine controls. |
Output Current Setting: | By single logarithmic control. |
Operating Mode: | Constant voltage or constant current with automatic |
Output Switch: | Electronic. Preset voltage and current displayed when off. |
Output Terminals: | 4mm terminals on 19mm (0.75”) pitch. |
Output Impedance: | Typically <5mΩ in constant voltage mode. |
| Typically >20kΩ in constant current mode. |
Output Protection: | Output will withstand up to 48V forward voltage. |
| Reverse protection by diode clamp for reverse currents up to 3A. |
The output will be tripped off if a fault causes the internal | |
Protection: | temperature to rise excessively. |
Load & Line Regulation: | <0.01% of maximum output for a 90% load change or 10% line |
| change. |
Ripple & Noise | Typically <2mVrms, <10mV |
(20MHz bandwidth): |
|
Transient Response: | <200µs to within 50mV of set level for 90% load change. |
Temperature Coefficient: | Typically <100ppm/°C |
Status Indication: | Output on lamp. Constant current mode lamp. |
METER SPECIFICATIONS
Meter Types: | Dual 4 digit meters with 14mm (0.56") LEDs. Reading rate 4 Hz. |
Meter Resolutions: | 10mV, 10mA |
Meter Accuracies: | Voltage 0.3% of reading ± 2digit, |
| Current 0.6% of reading ± 2digit |
GENERAL
AC Input: | Factory set for: 110V - 120V AC ±10% or 220V - 240V AC ±10%, |
| 50/60Hz. Installation Category II. |
Power Consumption: | 800VA max. |
Operating Range: | +5ºC to +40ºC, 20% to 80% RH. |
Storage Range: | −40ºC to + 70ºC. |
Environmental: | Indoor use at altitudes up to 2000m, Pollution Degree 2. |
Safety: | Complies with EN61010−1. |
EMC: | Complies with EN61326. |
Size: | 140 x 160 x 320mm (WxHxD). |
Weight: | 3.6kg |
3