Xantrex Technology 806-1840-02, 806-1020, 806-1055, 806-1840-01 manual Troubleshooting Reference

Models: 806-1055-02 806-1055 806-1020 806-1840-01 806-1840 806-1840-02

1 64
Download 64 pages 12.33 Kb
Page 51
Image 51

 

 

 

Troubleshooting Reference

 

Table 2 Troubleshooting Reference

 

 

 

 

 

 

 

 

Problem

Possible Cause

Solution

 

 

 

 

 

Low output voltage

You are using a voltmeter that cannot

Use a true RMS reading voltmeter such as the Fluke 87.

 

(96 volts AC–104 volts AC) during Inverter

accurately read the RMS voltage of a

 

 

 

mode.

modified sine wave.

 

 

 

 

 

 

 

No output voltage. The status LED is red.

AC shore power is not available or out of

operating range and the inverter has shut down with the display

 

 

screen showing one of the following error codes:

 

 

 

 

 

 

• Low input voltage (fault code )

• Check the DC connections and the cable.

 

 

 

Recharge the battery.

 

 

 

 

 

 

• High input voltage (fault code )

• Verify the unit is connected to a 12V battery.

 

 

 

• Check the voltage regulation of the external charging system

 

 

 

 

(if any).

 

 

 

 

 

 

• Unit overload or AC output short

• Reduce the load. Make sure the load does not exceed the

 

 

circuit (fault code )

 

output rating.

 

 

 

 

 

 

• Thermal shutdown (fault code )

• Allow the unit to cool off.

 

 

 

• Reduce the load if continuous operation is required.

 

 

 

• Improve ventilation. Make sure the inverter’s ventilation

 

 

 

 

openings are not blocked.

 

 

 

 

 

 

• AC transfer relay has overheated

• Improve ventilation. Make sure the inverter’s ventilation

 

 

(during shore power mode).

 

grille is not blocked.

 

 

 

Reduce the load.

 

 

 

 

 

 

975-0390-01-01

37

Page 51
Image 51
Xantrex Technology 806-1840-02, 806-1020, 806-1840-01, 806-1055-02 manual Troubleshooting Reference

806-1055-02, 806-1055, 806-1020, 806-1840-01, 806-1840 specifications

Xantrex Technology is renowned for its innovative power solutions, and among its extensive product lineup, the model numbers 806-1840-02, 806-1840-01, 806-1020, 806-1055, and 806-1055-02 stand out for their sophisticated features and reliable performance. These models are primarily designed to meet the diverse energy needs in off-grid, mobile, and backup power applications.

The Xantrex 806 family is characterized by its versatility and high efficiency. One of the standout features across these models is their pure sine wave inverter technology. This technology ensures that the power output closely mimics utility-provided electricity, making it safe to use with sensitive electronics such as computers and medical equipment. The clean, reliable power allows users to operate a variety of appliances without the risk of damaging electrical devices.

Another key characteristic is the ability of these inverters to provide a robust surge capability. This is crucial for starting up heavy equipment or appliances that require a higher initial power draw, such as refrigerators and air conditioners. Users can feel confident knowing that these inverters can handle demanding loads without compromising performance.

Scalability is also a notable feature of the Xantrex 806 models. Users can easily integrate multiple units to expand their power capacity, making them suitable for anything from small RVs to larger off-grid installations. The inverters include advanced communication features, allowing for easy monitoring and management of energy consumption via remote control systems.

Furthermore, these models incorporate user-friendly designs with features aimed at enhancing usability. For instance, the LED indicators provide real-time information about the operational status and battery levels, enabling users to quickly assess their power system’s performance.

Durability and reliability are critical considerations for any power solution, and the Xantrex 806 series meets these demands effectively. Built with high-quality materials, these inverters are designed to withstand the rigors of daily use in various environments, from remote camping sites to urban settings. With built-in safety features such as overload protection, short circuit protection, and thermal shutdown, they provide peace of mind for users.

In summary, the Xantrex Technology models 806-1840-02, 806-1840-01, 806-1020, 806-1055, and 806-1055-02 exemplify advanced engineering in power inverter technology. With their pure sine wave output, impressive surge capability, scalability, and durable construction, they offer reliable solutions for users seeking effective energy management in diverse applications.