If an AC product rated higher than 100 W is plugged into the XPower inverter, the inverter will shut down. The red fault light comes on.

If the XPower inverter exceeds a safe operating temperature, due to insufficient ventilation or a high-temperature environment, it automatically shuts down. The red fault light comes on.

Should a defective battery charging system cause the battery voltage to rise to dangerously high levels, the XPower inverter automatically shuts down. The red fault light comes on.

CAUTION

Although the XPower inverter incorporates protection against over-voltage, it may still be damaged if the input voltage exceeds 16 V.

In the event of an overload, low battery voltage or overheating, the XPower inverter automatically shuts down.

14

Page 19
Image 19
Xantrex Technology 975-0205-01-01 manual