Stacking Inverters
Precautions
•Only stack the same models of the RV inverter. For example, stack an RV2012 only with an RV2012.
•Use only a Xantrex stacker cable, available in RV Series External Shunt Kit (part #2813). It is not a standard telephone cable.
•Connect AC neutrals together close to the inverters. Keep input and output neutrals isolated.
•Connect the inverter’s battery negative terminals together according to this manual.
•Make all AC and DC connections and verify that they are made in accordance with this manual. Make sure that all connections are tight (especially the DC side). Connect the stacker cable to each inverter’s stacking port.
•Each inverter must be turned on individually before AC power will be available.
DC Connections for Stacked Inverters
Connection with One DC
disconnect device, connect the units and battery as follows: Connect the negative terminals of the inverters together, and then attach one of the negatives to the battery. Next connect the positive terminals of the inverters together, and attach one to the battery. Place the DC
+
Battery
DC
+ | RV Series | |
– | Inverter | |
Stacker cable | ||
| ||
+ | RV Series | |
– | Inverter | |
|
Connection with Two DC
Once the inverters are connected to the battery as described above, connect the Xantrex stacker cable between stacker ports.
+
Battery
DC
+ | RV Series | |
– | Inverter | |
Stacker cable | ||
| ||
+ | RV Series | |
– | Inverter | |
|
18