Xantrex RV Series Inverter/Charger Owner’s Manual
Technical Information
RV Series Specifications
| Models |
|
|
| RV2012 | RV2512 | RV3012 |
Continuous Power @ 25°C | 2000 watts | 2500 watts | 3000 watts |
Max AC Current | 16.6 amps | 20.8 amps | 25 amps |
Efficiency | 94% Maximum | 94% Maximum | 94% Maximum |
Input Current |
|
|
|
Search Mode | 0.055 amps | 0.070 amps | 0.080 amps |
Full Voltage | 0.550 amps | 0.600 amps | 0.650 amps |
At Rated Power | 200 amps | 250 amps | 300 amps |
Short Circuit | 600 amps | 800 amps | 900 amps |
Nominal Input Voltage | 12 VDC | 12 VDC | 12 VDC |
Input Voltage Range | |||
Auto Low Battery Protection | 11 V or defeated | 11 V or defeated | 11 V or defeated |
Voltage Regulation— | ±5% | ±5% | ±5% |
Maximum |
|
|
|
Voltage | ±2.5% | ±2.5% | ±2.5% |
Output Waveform | Modified sine | Modified sine | Modified sine |
Power Factor allowed | |||
Frequency Regulation | 60Hz ± .04% | 60Hz ± .04% | 60Hz ± .04% |
Standard Output Voltage | 120 VAC | 120 VAC | 120 VAC |
Adjustable Load Sensing | 5 to 40 watts | 5 to 40 watts | 5 to 40 watts |
Series Operation for 240 VAC | yes | yes | Yes |
Forced Air Cooling | Variable Speed | Variable Speed | Variable Speed |
Automatic Transfer Relay | 30 amps at 240 VAC or 50 amps at 120 VAC (field configurable) | ||
Adjustable Charge Rate | |||
Number of Charging Profiles | 2 (lead acid, sealed) | 2 (lead acid, sealed) | 2 (lead acid, sealed) |
Yes | Yes | Yes | |
Temperature Comp Probe | Optional | Optional | Optional |
Remote Control | Optional: RC6, RC7, | Optional: RC6, RC7, | Optional: RC6, RC7, |
| RC7GS | RC7GS | RC7GS |
Environmental Characteristics |
|
|
|
Operating Ambient Temp | 0°C to +50°C | 0°C to +50°C | 0°C to +50°C |
Unit Weight (lbs./kg) | 45/20.5 | 50/22.7 | 60/27.2 |
Dimensions (L × W × H) | 15.5” ×13.12” × 7.25” | 15.5” ×13.12” × 7.25” | 15.5” ×13.12” × 7.25” |
Mounting | Shelf mount only | Shelf mount only | Shelf mount only |
Approvals |
| UL and cUL Listed to UL458 and CSA107.1 |