Transient Load Response:

<250us to within 50mV of set level for a 5% to 95% load change.

Temperature Coefficient:

Typically <100ppm/°C

Status Indication:

Output on lamp.

 

Constant voltage mode lamp.

 

Constant current mode lamp.

 

Unregulated (power limit) lamp

 

Trip message on display.

METER SPECIFICATIONS

Meter Types:

Dual 4 digit meters with 12.5mm (0.5") LEDs. Reading rate 4 Hz.

Meter Resolutions:

10mV, 10mA

Meter Accuracies:

Voltage 0.1% of reading ± 2 digits,

 

Current 0.3% of reading ± 2 digits

GENERAL

AC Input:

110V – 240V AC ± 10%, 50/60Hz.

 

Installation Category II.

Power Consumption:

1250VA max.

Operating Range:

+5ºC to +40ºC, 20% to 80% RH.

Storage Range:

40ºC to + 70ºC.

Environmental:

Indoor use at altitudes up to 2000m, Pollution Degree 2.

Safety:

Complies with EN61010-1.

EMC:

Complies with EN61326.

Size:

210 x 130 x 375mm (WxHxD) half rack width x 3U height (optional

 

rack mounting kit available).

Weight:

6kg

4

Page 5
Image 5
Xantrex Technology XPF 60-20 manual Meter Specifications