Transient Load Response: | <250us to within 50mV of set level for a 5% to 95% load change. |
Temperature Coefficient: | Typically <100ppm/°C |
Status Indication: | Output on lamp. |
| Constant voltage mode lamp. |
| Constant current mode lamp. |
| Unregulated (power limit) lamp |
| Trip message on display. |
METER SPECIFICATIONS
Meter Types: | Dual 4 digit meters with 12.5mm (0.5") LEDs. Reading rate 4 Hz. |
Meter Resolutions: | 10mV, 10mA |
Meter Accuracies: | Voltage 0.1% of reading ± 2 digits, |
| Current 0.3% of reading ± 2 digits |
GENERAL
AC Input: | 110V – 240V AC ± 10%, 50/60Hz. |
| Installation Category II. |
Power Consumption: | 1250VA max. |
Operating Range: | +5ºC to +40ºC, 20% to 80% RH. |
Storage Range: | −40ºC to + 70ºC. |
Environmental: | Indoor use at altitudes up to 2000m, Pollution Degree 2. |
Safety: | Complies with |
EMC: | Complies with EN61326. |
Size: | 210 x 130 x 375mm (WxHxD) half rack width x 3U height (optional |
| rack mounting kit available). |
Weight: | 6kg |