Product: 8700 MICR | PSDS No.: 0800B |
Section V - Emission/Exposure Information*
Light Source
Light Path is internal to the printer and shielded to prevent light leakage or direct viewing. Meets BRH requirements for operator safety.
Electromagnetic Emissions
FCC/DOC: Class/Level A
Audible Noise | TLV |
75.2 db | 85 db (A) |
Ozone** | TLV: |
0.009 ppm | 0.1 ppm |
Total Dust** | TLV |
0.04 mg/m3 | 10 mg/m3 |
Selenium | TLV |
Arsenic** | PEL |
0.3 ug/m3 | 10 ug/m3 |
Tellurium | TLV |
*TLV (Threshold Limit Value) and PEL (Permissible Exposure Level) respectively set by American Conference of Government Industrial Hygienists and by Occupational Safety and Health Administration. These levels are considered maximum exposure permitted to ensure no health hazard. TWA (Time Weighted Average) for a normal eight hour workday.
**Emissions data taken in a 28 m3 room with 1/2 room change per hour for service personnel exposure only. Customer operator exposure level to be lower than levels noted. Emissions data taken from the 9700 MICR Emissions Report.
All measurements were made on products performing within established operating specifications and received recommended maintenance procedures. Xerox certifies that this product meets or exceeds the applicable standards for safety and emissions.