Installation Preparation Document (for physical installation of the product only)
Xerox DocuTech 6100/6115/6135
Customer Support
The Xerox Customer Support Center is available to provide general information, answer questions, and take service calls. You can reach the Customer Support Center at the following
United States |
|
Your Xerox Analyst will provide
Space Requirements
The diagram below is provided as a representation only of the space envelope required for installation of Xerox equipment. Diagram is a representation only and not drawn to scale.
|
|
|
|
|
|
|
| D |
|
|
|
|
|
|
|
| |
|
|
| D o c u T e c h 6 1 x x |
|
|
|
| E |
|
|
|
|
|
|
| P | |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| T |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| H |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
W ID T H
R e p r e s e n ta tio n o n ly .
Note: The 6100, 6115, 6135 are available with and without a stand to support the controller. If a stand is ordered, it will be positioned to the left of the printer, within the service space envelope. If no stand is ordered, the controller will be placed on the floor to the left of the printer in the service space envelope.
Note: The dimensions shown below provide the overall service space required, including the space to the nearest obstruction. The dimensions are in inches and are absolute minimums.
| With stand | Without stand | ||
Configuration | Width | Depth | Width | Depth |
6100, 6115, 6135 | 243.0" | 114.0” | 240.0” | 114.0" |
with interposer, and |
|
|
|
|
Finisher |
|
|
|
|
6100, 6115, 6135 | 196.0" | 114.0” | 193.0” | 114.0" |
without Interposer, |
|
|
|
|
with Finisher |
|
|
|
|
Electrical Requirements
Digital Front End (DFE) Controller Platform:
Line Options: |
|
|
| Dedicated | |||||
Voltage |
|
|
|
| 110V | ||||
Amperage | 15 |
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
Cycles |
|
|
|
| 60 Hz | ||||
|
|
|
|
|
|
|
|
|
|
15 amp Receptacle Xerox Part No. |
|
|
| 600S3704 | |||||
20 amp Receptacle Xerox Part No. |
|
|
| 600S3703 | |||||
Receptacle NEMA Part No. | 5 - 20R or 5 - 15R | ||||||||
|
|
|
|
|
|
|
|
|
|
Receptacle Diagram |
|
|
|
|
|
|
|
|
|
|
|
|
|
| or |
•All controller configurations require a 110VAC, 15 Amp grounded receptacle for the outlet strip that provides receptacles for the controller and its peripheral devices (monitor, modem, CDROM drive, and tape drive)
•Adapters that eliminate the ground connection to the outlet can not be used.
•Xerox provides 15 feet of cabling with Teflon coating (Plenum rated), to connect the controller to the Processor/Finisher.
Interposer
Line Options: | Dedicated | ||
Voltage | 120 |
| |
|
|
|
|
Amperage | 15 |
| |
|
|
|
|
Cycles | 60 Hz | ||
|
|
|
|
Receptacle Xerox Part No. | 600S3704 | ||
|
|
|
|
Receptacle NEMA Part No. | 5 - 15R | ||
Power Cord Length | 6 feet | ||
|
|
|
|
Receptacle Diagram |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
Electrical Requirements
Printer/Finisher/Binder
Line Options: | Single | |||
| Source | |||
|
|
|
|
|
Voltage | 208/240 |
| ||
|
|
|
|
|
Amperage | 50 |
|
|
|
|
|
|
|
|
Cycles | 60 Hz | |||
|
|
|
|
|
Receptacle Xerox Part No. | 600S3779 | |||
|
|
|
|
|
Receptacle NEMA Part No. | ||||
|
|
|
|
|
Power Cord Xerox Part No. | 98K19950 | |||
| 117K9940 | |||
|
|
|
|
|
Receptacle Diagram |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*Dedicated power outlets required. Ensure each power cord has a separate circuit that cannot be shared with other devices.
*15 ft. power cord(s) are provided, however, the distance from the equipment to the outlet should not exceed 13.1 ft.
Installation Considerations
•There should be a minimum of 78 inches (1,981mm) clearance from the floor to the nearest overhead obstruction.
•Mobility Assist Device - The optional mobility assist device reduces the installation clearance required to 30 inches (760mm) at the processor end of the printer and 15 inches (380 mm) at the finisher end.
•For proper operation, the printer must be perfectly level. The floor must be level within 2 degrees in any direction. On floors less than 2 degrees out of level, installation personnel install a leveling kit to level the machine.
•If the floor is more than 2 degrees out of level, this condition cannot be corrected by the leveling kit. Another suitable location must be found for the printer to be installed properly.
•A minimum
•A minimum of 36 inches of clearance is required in the back of each component for general service clearance.
Please ensure electrical, space, and supplies are available prior to equipment delivery.