![...it couldn’t be simpler!](/images/new-backgrounds/44839/4483913x1.webp)
...it couldn’t be simpler!
Installing Digitemp from within the room at high or low levels requires only a standard 13 amp electrical supply.
Designed for low cost installation, Digitemp is simple to fit requiring only two discreet holes to an external wall. Using a patented folding grille system, Digitemp can be installed entirely from inside the property making it ideal for apartments and
When operating in cooling only mode, condensate is removed through water evaporation on the condenser therefore a drainage pipe is not necessary. In models with a heating function, the unit requires condensate to be removed through a small drainage pipe.
Only external evidence is two discreet grilles
1 Select the position of the unit (see diagram for optimum positioning). Where possible the unit should be positioned towards the centre of the selected external wall
2 Drill holes for vents at a sloping angle to the external wall to allow for drainage in heating mode
3
4 From within the room, feed the discreet folding grilles through the inlet and outlet vents
5 Hard wire the unit to a ring main spur