Xtant M Series manual Troubleshooting, Diagnostic Led’S

Models: M Series

1 21
Download 21 pages 45.98 Kb
Page 19
Image 19
TROUBLESHOOTING

TROUBLESHOOTING

DIAGNOSTIC LED’S

The Red LED indicates that the amplifier is on.

The Yellow LED indicates that an over-current condition (low imped- ance) exist and will turn the amp’s output power down to maintain unin- terrupted operation. The Yellow LED will light if a speaker load falls below the M Series’ 2Ω rating and/or a speaker lead / speaker voice coil is shorted.

The Orange LED indicates that an over-heating condition exists and will turn the amp’s output power down to maintain uninterrupted operation. The Orange LED will light if the heatsink temperature exceeds rated spec due to poor ventilation.

SYMPTOM/CONDITION

CAUSE

SOLUTION

Red LED not on. No Sound.

Loss of 12V Power at Amplifier

Check out-board fusing

 

 

Check +/– 12 Volt connections

 

 

Measure for + 12 Volts or higher

 

 

@ amp. Check Turn-On lead

Red LED on. No Sound.

No Input Signal

Check integrity of RCA cables

 

 

Check connection at amp and

 

 

head unit.

Red LED on. No Sound.

Loose Speaker Wires

Check integrity of speaker

 

 

connection at amp and speakers.

Red LED on. No Sound.

Lack of Turn-On Voltage

Voltage @ Turn-On lead needs

 

 

to be 8 Volt minimum

Red LED on. No Sound.

Missing Accessory Port Jumper

Check Port Jumpers, two jumpers

 

 

per port are required. Check

 

 

jumper alignment, jumper must

 

 

be seated properly.

Red LED on. No Sound.

Accessory module is not

Be sure “key” on module connector

 

installed properly

and port are aligned when

 

 

installing module. Reseat module

 

 

to insure proper connection.

Alternator/System Noise

Induced noise / ground loop

“Enable” Balanced Input

18

Page 19
Image 19