27
3.
Press the [SAVE/ENT] button to carry out the copy op-
eration.
* To cancel the copy operation, press any button except for
the [SAVE/ENT] and [SHIFT] buttons (the jog dial will also
cancel the operation).
The following display appears after the copy operation is
complete.
Trigger Setup Edit
Completed!
TRIG7 SPRej (Specified Rejection Level)
SPRej [Range] 0 to 9
from [Range] 1 to 9, 56
This setting is used to prevent cross talk between the input jack
assigned in the upper half of the display and the input jack as-
signed in the “from=” setting.
After an event occurs from the pad that is assigned in the “from=”
setting, the pad assigned in the upper half of the display will not
sound for a certain length of time unless the input level is greater
than the value set here. Larger values will require a greater input
level in order to produce a trigger event.
A “from=56” setting assigns both trigger inputs 5 and 6.
TRIG8 Copy to Input (Trigger Setup Copy)
This function copies all data settings in pages [TRIG2 Type (Pad
Type)] through [TRIG7 SPRej (Specified Rejection Level)] to an-
other input jack.
CAUTION
When the Trigger Setup Copy operation is carried
out, the trigger setup data will be replaced with the
settings of the copy source.
Procedure
1.
Hit a pad to select the copy source (trigger input) from
which the data will be copied.
Rotate the jog dial and assign the copy destination (trig-
ger input) to which the data will be copied.
2.
Press the [SAVE/ENT] button. The following displa y ask-
ing your confirmation to proceed with the copy operation.
TRIG7 ¡snare 0%
–SPRej=0from= 1‚
TRIG8 ¡snare
–Copy to Input=2
TRIG8 ¡snare
–Copy to Input=2
Trigger Input (jack) to be copied
Destination Trigger Input to which the
data will be copied to
Input Copy to 2
Are you sure ?