Battery Charging

 

761-081a

2

1

 

 

762-042

12v

762-043a

w

q

763-238a

AE00825

Battery Charging

NOTE:

The generator DC rated voltage is 12V.

1.Wind the battery charging lead (furnished as an accessory) 2 or 3 turns around the handle and plug into DC receptacle.

NOTE:

9Make connections to the battery after starting the engine.

9Clamp the red wire to the positive (+) terminal and the black wire to the negative (-) terminal of the battery. Do not reverse these positions.

1Red

2 Black

2.Start the engine.

3.Press in the DC protector and install the battery.

cC

9Be sure the battery leads are properly connect- ed.

9Be sure the breather hose is properly connect- ed and is not damaged or obstructed.

9Reduce the load to the specified generator rated output if the DC protector turns off. If it turns off again, consult a Yamaha dealer.

NOTE:

Press to reset the DC protector.

1“ON”

2 “OFF”

NOTE:

9At full charge, electrolyte specific gravity is between 1.26 and 1.28.

9Check specific gravity hourly.

– 20 –