ENGLISH

DEUTSCH

FRANÇAIS

ESPAÑOL

19
MIC LINE AMPLIFIER

Specifications

Electrical Characteristics

0 dBu is referenced to 0.775 V rms.

General Specifications

Conditions MIN TYP MAX UNIT
Total Harmonic Distortion (THD+N)
20 Hz - 20 k Hz @ +14 dBu, 10 k ohms,
GAIN Maximum 0.1 %
20 Hz - 20 k Hz @ +14 dBu, 10 k ohms,
GAIN Minimum 0.01 %
Frequency Response
20 Hz - 20 k Hz @ +4 dBu, 10 k ohms,
GAIN Maximum 10 0.5 dB
20 Hz - 20 k Hz @ +4 dBu, 10 k ohms,
GAIN Minimum 0.5 0 0.5 dB
Hum & Noise (20 Hz - 20 k Hz)
PAD OFF, GAIN Maximum
( Sensitivity = 60 dBu )
128
(68 dB S/N) dBu
PAD ON , GAIN Maximum
( Sensitivity = 34 dBu )
99
(65 dB S/N) dBu
Rs=150 ohms PAD OFF, GAIN Minimum
( Sensitivity = 16 dBu )
108
(92 dB S/N) dBu
Hum & Noise are measured with a 6 dB/octave
filter @12.7 k Hz; equivalent to a 20 k Hz filter
with infinite dB/octave attenuation.
PAD ON , GAIN Minimum
( Sensitivity = +10 dBu )
82
(92 dB S/N) dBu
Maximum Voltage Gain CH IN to CH OUT 64 dB
Crosstalk
Adjacent Inputs @ 1 k Hz –90 dB
PAD ON,
GAIN Minimum @ 10 k Hz 70 dB
CH INPUT GAIN control variable 44 dB
CH INPUT PAD switch 26 dB
CH High Pass Filter 80 Hz, 12 dB/octave
Turn over /roll-off frequency of shelving : 3 dB below maximum variable level.
Phantom Power +48 V DC is applied to balanced inputs for powering condenser microphones via 6.8 k ohms
current-limiting/isolation resistors.
CH PEAK LED One red LED per channel. Comes on when post GAIN signal level reaches +17 dBu.
CH SIGNAL LED One green LED per channel. Comes on when post GAIN signal level reaches -10 dBu.
Included Accessories
Power Supply Cord, Euroblock Connectors ( 3P x 8 ), Rubber Feet ( x 4 ), Owner's Manual
Power Consumption 25 W
Dimensions (W x H x D) 480 mm x 44 mm x 375.5 mm
Weight 4.7 kg