Filter Element Cleaning
To ensure adequate cooling air intake, the filter elements must be cleaned when they have become clogged. Follow the description below to clean the filter elements.
1.Make sure that the power to the amplifier is turned off.
2.Disconnect the power plug from the AC outlet.
3.Remove the two screws that secure the front filter grilles to the amplifier.
4. Remove the filter elements, and wash them in plain water. If the filter elements are exceptionally dirty, mild detergent may be used.
5. Dry the filter elements completely.
Never replace the filter elements while they are still wet.
6. Replace the filter elements on the air intakes, hook the front filter grilles on the amplifier, and secure them using the screws. (The replacement part number of the filter element is WH66270.)
Front filter grille
Troubleshooting
Filter element
The following table lists the main causes of abnormal operation and the corrective measures required, as well as the protective circuit operation in each case.
Indicator(s) | Possible Cause | Remedy | Protection Circuit | |
|
|
|
| |
| There is a short at a speaker ter- | Locate and correct the cause of |
| |
| minal, amplifier terminal, or |
| ||
| the short. |
| ||
| wire. |
| ||
CLIP indicator |
| The PC limiter circuit operates to | ||
|
| |||
| Use a speaker system with an | |||
lights. |
| protect the power transistors. | ||
| The amplifier load is excessive. | impedance of at least 2 ohms |
| |
| (STEREO/PARALLEL mode) or |
| ||
|
|
| ||
|
| 4 ohms (BRIDGE mode). |
| |
|
|
|
| |
|
| Check the ventilation slots and |
| |
TEMP indica- | The heat sink temperature has | clean the filter elements to pro- | The TEMP indicator lights up to | |
tor lights. | exceeded 85˚C. | vide better airflow around the | indicate temperature warning. | |
|
| amplifier. |
| |
|
|
|
| |
|
| Check the amplifier ventilation |
| |
|
| conditions and take appropriate | The thermal protection circuit | |
| The heat sink temperature has | measures to improve the airflow | ||
PROTEC- | operates to protect the power | |||
exceeded 85˚C. | around the amplifier. | |||
transistors. | ||||
TION indica- |
| Also, clean the filter elements to | ||
|
| |||
tor lights. |
| ensure proper airflow. |
| |
|
|
|
| |
| A DC voltage is detected at the | Consult your dealer or the near- | The power supply shuts down to | |
| amplifier’s output. | est Yamaha service center. | protect the speaker system. | |
|
|
|
| |
MUTE indica- | There is a short at a speaker ter- | Locate and correct the cause of | The MUTE circuit operates to | |
tor lights. | minal. | the short. | protect the power transistors. | |
|
|
|
|
T5n/T4n/T3n Owner’s Manual 11