Controls and Functions

Front Panel

2

0

9

1

4 3

1POWER switch and indicator

Press to toggle the power on or off. The POWER indicator lights up green when the power is ON.

If the amplifier is connected to an amp control unit such as the ACU16-C and the amplifier has been commanded to enter STANDBY mode, this indicator will light orange.

2TEMP indicatorLights up red if the heat sink temperature exceeds 85°C (185°F).3PROTECTION indicator

When the protection system is active, the indicator lights in red. No sound will be output from the speakers, since the speakers are automatically disconnected from the ampli- fier’s outputs.

The protection system actives in the following situations:When the amplifier is turned on

The protection system actives for approximately 10 seconds when the amplifier is turned on. After 10 sec- onds, the protection system deactivates automatically and the amplifier is ready for normal operation.

If the amplifier overheats

The protection system activates if the heat sink tem- perature exceeds 85°C (185°F). The amplifier is muted if the heat sink temperature exceeds 90°C (194 °F). The amplifier operates normally after the ampli- fier cools down.

4REMOTE indicator

This indicator will light green if the amplifier is being controlled by an amp control unit such as ACU16-C.

5CLIP indicator

Lights up red when the output signal distortion on the corre- sponding channel rises above 1% — indicating that “clip- ping” has occurred because the signal level is too high.

6SIGNAL indicator

Lights up green when the corresponding channel’s output level exceeds 1 Vrms (equivalent to 0.2 W into an 8 ohms load, 0.4 W into a 4 ohms load or 0.8 W into a 2 ohms load).

6 5 6

T5n

7 8

9

0

7MUTE indicator

This indicator will light red if the amplifier is muted by an amp control unit such as the ACU16-C. This indicator will also light red while the PROTECTION indicator is ON.

8Volume control knobs

Each control knob adjusts the volume of the corresponding channel, in 31 steps from -dB to 0 dB.

Note: Screw holes for security cover

These four screw holes are for attaching a security cover to protect the volume setting. Since a security cover and screws are not included in the ampli- fier, please prepare a security cover the same size as indicated below and four M3 screws.

30 mm

108 mm

9Air intakes

The amplifier uses forced-air cooling. The variable speed cooling fan draws air in from the front and exhausts it through the rear. The cooling fan speed varies depending on the heat sink temperature: It operates at low speed when it is below 40 °C (104 °F), increases in speed according to increases in temperature, and operates at high speed when temperature exceeds 60 °C (140 °F). Please be sure that you do not block the air intakes or exhaust vents. Also, clean the filter elements regularly. If the air intakes are clogged with dust or debris, the amplifier will overheat, which may result in the amplifier shutting down.

Front

Rear

Air

Air

intake

exhaust

0Screw holes for handles

These four screw holes are for the included handles. Fix the handles to the amplifier, using the included flat-head screws.

6 T5n/T4n/T3n Owner’s Manual