Input and Output Patching 49
DM1000 Version 2—Owner’s Manual
4
Connections and Setup
Input and Output Patching
The DM1000 is designed to enable you to patch (assign) signals to Inputs and Outputs.
This section explains how to view the signals patched to Inputs and Outputs and change the
assignment.
Patching Input Channels
By default, the Input Channels are patched as follows:
•INPUT connectors 1–16.................... Input Channels 1–16
•Channels 1–8 of Slot 1....................... Input Channels 17–24
•Channels 1–8 of Slot 2....................... Input Channels 25–32
•Outputs 1–2 of Internal Effects
Processor 1–4...................................... Input Channels 33–40
•L&R of 2TR IN DIGITAL
connectors 1–2.................................... Input Channels 41–44
•OMNI IN connectors 1–4..................Input Channels 45–48
Follow the steps below to view or change the patching.
1 Press the DISPLAY ACCESS [INPUT PATCH] button repeatedly until the fol-
lowing page appears.
Inputs and Slot channels that are currently assigned to Input Channels are shown in the
parameter boxes (1) beneath the channel numbers. The parameter indicators are
explained below:
•– .....................................No assignment
•AD1–AD16....................INPUT connectors 1–16
•OMN1–OMN4............. OMNI IN connectors 1–4
•S1-1–S116......................Channels 1–16 of Slot 1
•S2-1–S216......................Channels 1–16 of Slot 2
•FX1-1–FX1-8................Outputs 1–8 of Internal Effects Processor 1
•FX2-1–FX2-2................Outputs 1–2 of Internal Effects Processor 2
•FX3-1–FX3-2................Outputs 1–2 of Internal Effects Processor 3
•FX4-1–FX4-2................Outputs 1–2 of Internal Effects Processor 4
•2D1L & 2D1R............... 2TR DIGITAL IN 1 (L/R)
Tip: If the data from a connected instrument fails to be input, or if you are unable to monitor
an OMNI OUT, check the I/O patching, as explained below:
1