XM4180/XM4080/XH200 Owner’s Manual 15

Current Draw

XM4180

XM4080

XH200

1/8 power is typical of program material with occasional clipping. Refer to these figures for most applications.
1/3 power represents program material with extremely heavy clipping.
Test signal: Pink Noise, bandwidth limited from 22Hz to 22kHz
1W = 0.860kcal/h, 1BTU = 0.252kcal
Note that Line Voltage [V] x Line Current [A] = [VA], not equals to [W].
Inrush current: 11A (100V), 13A (120V), 25A (240V)
Line Current (A) Power (W) Thermal Dissipation
100/120V 230/240V In Out Dissipated Btu/h kcal/h
standby 0.08 0.04505174
idle 1.0 0.5 40 0 40 137 34
1/8 power 8/ch 4.8 2.6 327 90 237 810 204
4/ch 6.8 3.7 460 115 345 1180 297
1/3 power 8/ch 11.3 6.2 793 240 553 1890 476
4/ch 15.9 8.8 1115 307 808 2760 695
Line Current (A) Power (W) Thermal Dissipation
100/120V 230/240V In Out Dissipated Btu/h kcal/h
standby 0.08 0.04505174
idle 1.0 0.5 40 0 40 137 34
1/8 power 8/ch 2.8 1.5 191 40 151 517 130
4/ch 4.5 2.4 303 58 245 837 211
1/3 power 8/ch 6.8 3.7 464 107 357 1220 307
4/ch 10.5 5.8 734 153 580 1980 499
Line Current (A) Power (W) Thermal Dissipation
100/120V 230/240V In Out Dissipated Btu/h kcal/h
standby 0.08 0.04505174
idle 1.0 0.5 40 0 40 137 34
1/8 power 3.7 2.0 250 50 200 683 172
43