2. ADDITIONAL VENTILATION

PRE-INSTALLATION CHECKS

1.12Where a hearth, fireplace, flue or chimney is provided or extended (including cases where a flue is provided as part of refurbishment work), information essential to the correct appliance and use of these should be permanently posted in the building, to meet Requirement J4 of the Building Regulations (England and Wales), F3.12 (Scotland).

2. ADDITIONAL VENTILATION

 

 

 

 

 

 

 

 

 

2.1 Additional ventilation will be required to comply with

 

 

 

 

 

 

 

 

 

the requirements of the Building Regulations. This

 

 

 

 

 

 

 

 

 

should be provided using a permanently open air vent, of

 

 

 

 

 

 

 

the size listed, which is positioned so that it is not liable

 

 

 

 

 

 

 

 

 

to be blocked both inside and outside the building.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

 

 

Elegance 200

Elegance 210

Elegance 220

Elegance 240

Elegance 250

Elegance 270

Elegance 280

 

 

 

 

 

 

 

mm

none

none

1100

none

550

550

1650

 

 

 

Additional Ventilation

 

 

cm

-

-

11

-

5.5

5.5

16.5

 

 

sq. inch

-

-

4.33

-

2.17

2.17

6.50

2.2 Extractor fans or cooker hoods should not be placed in the same room or space as the appliance.

2.3 If any of these checks reveal problems, do not proceed with the fitting of the appliance until they have been rectified.