Yeoman 8455, 8456 manual Changing Between GAS Types, Short Spares List

Models: 8456 8455

1 27
Download 27 pages 21.28 Kb
Page 25
Image 25

SERVICING INSTRUCTIONS

REPLACING PARTS

10. CHANGING BETWEEN GAS TYPES

10.1In order to change between gas types you need to change the following items.

Pilot Unit

Control Valve

Main Injector

Aeration Plate (if required)

Databadge

The relevant parts can be ordered as a conventional kit from Yeoman. Always quote the stove type and serial number when ordering spare parts.

**NOTE: THE CONTROL VALVE IS FACTORY PRESET FOR CORRECT GAS TYPE AND MODEL. A NEW UNIT WILL NEED TO BE ORDERED WHEN CHANGING BETWEEN GAS TYPES.

11. CONTROL UPGRADE

See Installation, section 1.

12. SHORT SPARES LIST

Component

NG

LPG

 

G20

G30

 

G31

 

20mb

29mb

 

37mb

Main Injector

IN0045

IN0030

 

IN0030

 

Aeration plate

N/A

N/A

ME1350

Pilot injector

PI0026

PI0015

Burner assembly

GZ5369

GZ5388

Thermocouple

 

PI0011

 

Magnetic unit

 

GC0092

 

Electrode

 

PI0053

 

Pilot Gasket

 

PI0052

 

Gas valve*

 

GC0088K

 

Ignition lead

 

GC0090

 

Standard upgrade kit

 

YM-8455

 

Thermostat/timer kit

 

YM-8456

 

 

 

 

 

 

Page 25
Image 25
Yeoman 8455, 8456 manual Changing Between GAS Types, Short Spares List