036-21217-001-B-1203

Steam Coil Performance @ 2 PSIG

Unit Model

CFM

Entering Air Dry Bulb Temperature

 

 

 

 

 

 

10

30

50

70

 

 

 

 

 

 

 

1800

140

126.6

113.1

99.7

CU060

 

 

 

 

 

2000

147.1

133

118.8

104.7

 

 

 

 

 

 

 

2200

153.6

138.9

124.1

109.3

 

 

 

 

 

 

 

3000

258.3

233.4

208.6

183.8

CU096

3200

266.6

241

215.3

189.7

 

 

 

 

 

 

 

3400

274.5

248.1

221.8

195.4

 

 

 

 

 

 

 

3600

282.1

255

227.9

200.8

CU120

 

 

 

 

 

4000

296.3

267.9

239.4

210.9

 

4400

309.5

279.8

250.1

220.3

 

 

 

 

 

 

 

5400

425.8

384.9

344

303.1

CU180

 

 

 

 

 

6000

447.4

404.4

361.4

318.4

 

 

 

 

 

 

 

6600

467.3

422.4

377.5

332.6

 

7200

569.6

514.9

460.2

405.5

CU240

 

 

 

 

 

8000

598.5

541

483.5

426

 

 

 

 

 

 

 

8800

625.3

565.2

505.1

445.1

 

 

 

 

 

 

 

9000

645.8

583.7

521.7

459.6

CU300

10000

677.1

612.1

547

481.9

 

 

 

 

 

 

 

11000

706.1

638.2

570.4

502.6

 

 

 

 

 

 

ïSteam Heating Coils are tube-in-tube ësteam distributingí type to eliminate risk of con- densate freezing.

ïCoils are constructed of 5/8 inch diameter outer copper tubes, with 3/8 inch diameter inner tubes. The outer tube is mechanically bonded to rippled aluminum plate fins. Coil casing is fabricated of heavy gauge galvanized sheet. Copper headers are complete with MPT connections.

ïAll coils are 1 row, 8 fins per inch.

Hot Water Coil Performance

Unit Model

GPM

CFM

 

Temperature Difference*

 

 

 

 

 

 

 

 

 

 

70

 

90

110

 

130

 

 

 

 

 

 

 

 

 

 

 

1800

62.4

 

80.8

99.3

 

117.8

CU060

10

 

 

 

 

 

 

 

2000

66.2

 

85.9

105.5

 

125.3

 

 

 

 

 

 

 

 

 

 

 

2200

69.9

 

90.6

111.4

 

132.3

 

 

 

 

 

 

 

 

 

 

 

3000

111.6

 

144.3

177.1

 

209.9

CU096

15

 

 

 

 

 

 

 

3200

116

 

150.1

184.1

 

218.3

 

 

 

 

 

 

 

 

 

 

 

3400

120.2

 

155.5

190.9

 

226.3

 

 

 

 

 

 

 

 

 

 

 

3600

124.3

 

160.8

197.3

 

234

CU120

15

 

 

 

 

 

 

 

4000

131.9

 

170.7

209.6

 

248.6

 

 

 

 

 

 

 

 

 

 

 

4400

138.9

 

179.9

220.9

 

262

 

 

 

 

 

 

 

 

 

 

 

5400

183.5

 

237.3

291.2

 

345.2

CU180

20

 

 

 

 

 

 

 

6000

194.6

 

251.7

308.9

 

366.2

 

 

 

 

 

 

 

 

 

 

 

6600

204.8

 

265

325.3

 

385.7

 

 

 

 

 

 

 

 

 

 

 

7200

257.6

 

332.7

407.9

 

483.2

CU240

35

 

 

 

 

 

 

 

8000

274.2

 

354.2

434.3

 

514.6

 

 

 

 

 

 

 

 

 

 

 

8800

289.6

 

374.3

459

 

543.9

 

 

 

 

 

 

 

 

 

 

 

9000

313.2

 

404.3

495.5

 

586.8

CU300

50

 

 

 

 

 

 

 

10000

333.6

 

430.7

527.9

 

625.3

 

 

 

 

 

 

 

 

 

 

 

11000

352.5

 

455.3

558.2

 

661.2

 

 

 

 

 

 

 

 

 

* Temperature difference between entering water and entering air temperature.

ïHot Water Heating Coils are constructed of 1/2 inch diameter copper tubes, mechanically bonded to rippled aluminum plate fins. Coil casing is fabricated of heavy gauge galvanized sheet. Copper tube headers are complete with MPT connections.

ïAll coils are 2 row, 8 fins per inch.

CU240 - 300

CU060 - 180

FIGURE 10 - HOT WATER & STEAM HEATING COILS PERFORMANCE DATA

Unitary Products Group

23

Page 23
Image 23
York CU060, CH060 manual HOT Water & Steam Heating Coils Performance Data

CU060, CH060 specifications

The York CU060 and CH060 units represent a noteworthy combination of efficiency and advanced technological capabilities in the realm of commercial heating and cooling. These models are widely recognized for their robust performance and reliability, making them ideal for a variety of applications.

The CU060 is an air-cooled chiller that excels in providing reliable cooling for medium to large commercial buildings. It employs advanced scroll compressor technology that significantly enhances efficiency during operation. This results in lower energy consumption while maintaining optimal cooling performance. The high-efficiency rating also aligns with environmental regulations, supporting organizations in their sustainability goals.

One of the standout features of the CU060 is its microchannel condenser coils, which facilitate improved heat exchange capabilities. This design not only reduces refrigerant charge but also enhances the overall energy efficiency of the unit. These coils are resistant to corrosion and require less maintenance, contributing to a lower total cost of ownership over time.

On the other hand, the CH060 is designed specifically for heating applications, utilizing a hot water or steam configuration. This unit is ideal for commercial spaces requiring effective climate control during colder months. The CH060 leverages advanced controls and monitoring technologies, allowing users to maintain desired temperature levels with precision. Its ability to integrate seamlessly with building management systems further adds to its appeal, facilitating automated control and real-time monitoring.

Both units are equipped with sound-dampening features to minimize operational noise, making them suitable for installations in noise-sensitive environments such as schools and hospitals. The compact design of the CU060 and CH060 allows for flexible installation options, making them suitable for limited-space applications.

Overall, York's CU060 and CH060 models are notable for their efficiency, innovative engineering, and adaptability to various commercial settings. They stand as reliable choices for organizations seeking to enhance their heating and cooling solutions while minimizing their environmental footprint. With a commitment to performance and sustainability, these units represent a forward-thinking approach to climate control in the commercial sector.