York DM 078 manual Features

Models: DM 078

1 48
Download 48 pages 45.33 Kb
Page 3
Image 3
FEATURES

 

 

 

 

 

 

 

 

246645-YTG-C-0708

 

Simplicity™ control board

Disconnect location

 

Filter access

Filter drier

 

w/screw connector for T-stat

 

(solid core)

 

 

(2” throw-away)

 

wiring and network connections (optional

 

disconnect switch)

 

 

 

 

 

 

 

Terminal block for

 

 

 

 

 

 

 

 

hi-voltage connection

 

 

 

 

 

 

Condenser section

 

 

 

 

 

 

 

 

 

Second model

 

 

 

 

 

 

 

 

nameplate

 

 

 

 

 

 

Slide-out motor and

 

inside hinged

 

 

 

 

 

 

 

 

 

 

 

 

 

blower assembly for

 

access panel

 

 

 

 

 

 

 

 

 

 

 

 

 

easy adjustment

 

Dual stage

 

 

 

 

 

 

and service

 

 

 

 

 

 

 

Belt-drive

 

cooling for

 

 

 

 

 

 

 

 

 

 

 

 

 

blower motor

 

maximum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

comfort

 

 

 

 

 

 

Power ventor motor

 

Compressor #2

 

 

 

 

 

 

 

 

 

 

 

 

 

20-gauge alumi-

 

access (high-

 

 

 

 

 

 

 

efficiency

 

 

 

 

 

 

nized steel tubular

 

compressor

 

 

 

 

 

 

heat exchanger for

 

w/crankcase

 

 

 

 

 

 

long life (stainless

 

heater)

 

 

 

 

 

 

steel option)

 

 

 

 

 

 

 

 

Two-stage gas

 

Base rails w/forklift

 

 

 

 

 

 

heating to maintain

 

slots (three sides)

 

 

 

 

 

Slide-out drain pan

warm, comfortable

 

and lifting holes

 

 

 

 

 

temperature

 

 

 

 

 

 

with steel 3/4” NPT,

 

 

 

 

 

 

 

Intelligent control

 

Roof curbs in eight- and

 

 

 

 

 

female connection

 

fourteen-inch heights. Roof

 

 

 

 

 

 

board for safe and

 

curbs for transitioning from

 

 

Side entry power

Compressor #1 access

efficient operation

 

York Sunline™ footprint to

Toolless

 

 

 

 

(high-efficiency compressor

 

 

and control wiring

 

the ZH Series footprints are

 

 

door latch

 

w/crankcase heater)

 

 

 

knockouts

 

 

 

 

also available (field-installed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

accessory)

 

 

 

 

 

 

 

FIGURE 1 - PREDATOR® COMPONENT LOCATION (DM 120 SHOWN)

 

FEATURES

 

 

 

 

Service windows have been placed in both condenser

Standard Efficiency– All standard efficiency units have

 

section walls. Rotation of the cover allows easy access

 

to the condenser coils for cleaning or inspection.

 

a minimum EER of 9.0. Gas/electric units have elec-

 

 

 

Both the unit control board and ignition control board utilize

 

tronic spark ignition and power vented combustion with

 

 

steady state efficiencies of 80%.

 

 

 

 

flash codes to aid in diagnosis of unit malfunctions. Unique

Service Friendly – The Predator® incorporates a num-

 

alarm codes quickly identify the source of the unit alarm.

 

All units use the same standard filter size. This stan-

 

ber of enhancements which improve serviceability.

 

 

 

dardization removes any confusion on which filter sizes

 

The motor and blower slide out of the unit as a common

 

 

 

are needed for replacement.

 

 

assembly. This facilitates greater access to all the indoor

 

The non-corrosive drain pan slides out of the unit to per-

 

airflow components, thus simplifying maintenance and

 

 

 

mit easy cleaning. The drain pan is accessed by remov-

 

adjustment.

 

 

 

 

 

 

 

 

 

ing the drain pan cover plate on the rear of the unit.

 

Service time is reduced through the use of hinged, tool-

 

 

 

Once the plate is removed, the drain pan slides out

 

less panels. Such panels provide access to frequently

 

through the rear of the unit.

 

 

inspected components and areas, including the control

 

All Predator® units have a second model nameplate

 

box, compressors, filters, indoor motor & blower, and the

 

 

heating section. The panels are screwed in place at the

 

located inside the control access door. This is to prevent

 

factory to prevent access by children or other unauthor-

 

deterioration of the nameplate through weathering.

 

ized persons. It is recommended that the panels be

Environmentally Aware – For improved Indoor Air

 

secured with screws once service is complete.

 

 

 

 

 

 

Quality, foil faced insulation is used exclusively through-

out the units.

Johnson Controls Unitary Products

3

Page 3
Image 3
York DM 078 manual Features