Image 19
HEATING PERFORMANCE DATA

 

 

 

 

 

 

 

 

036-21031-004 Rev. A (0603)

 

 

 

 

 

 

 

 

 

 

 

HEATING PERFORMANCE DATA

 

 

 

 

 

 

 

 

 

 

CONDENSING UNIT MODEL NO

E4FH30S06

 

 

 

 

 

 

 

 

EVAPORATOR COIL MODEL NO

G2FD030(S,H)17

 

 

 

 

 

 

 

 

AIR TEMP.

AIR TEMP.

 

 

 

 

ID CFM

 

 

 

 

 

ENTERING

ENTERING

 

950

 

 

1050

 

 

 

1150

 

OUTDOOR

INDOOR

 

 

 

 

 

 

 

 

 

 

MBTUH

K.W.

C.O.P.

MBTUH

K.W.

C.O.P.

 

MBTUH

K.W.

C.O.P.

UNIT

COIL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

33.7

2.53

4.02

33.9

2.51

4.09

 

34.1

2.49

4.16

60

 

 

 

 

 

 

 

 

 

 

 

70

26.4

2.67

3.66

33.1

2.66

3.76

 

33.8

2.65

3.87

 

 

 

 

 

 

 

 

 

 

 

 

 

80

25.7

2.85

3.29

32.3

2.84

3.43

 

33.5

2.83

3.56

 

 

 

 

 

 

 

 

 

 

 

 

 

60

23.0

2.34

3.62

29.2

2.33

3.68

 

29.6

2.57

3.74

47

 

 

 

 

 

 

 

 

 

 

 

70

22.0

2.46

3.26

28.0

2.46

3.33

 

28.6

2.70

3.40

 

 

 

 

 

 

 

 

 

 

 

 

 

80

21.0

2.61

2.89

26.8

2.62

2.98

 

27.6

2.87

3.06

 

 

 

 

 

 

 

 

 

 

 

 

 

60

21.3

2.25

3.41

26.8

2.38

3.45

 

27.1

2.26

3.48

40

 

 

 

 

 

 

 

 

 

 

 

70

19.9

2.35

3.06

25.2

2.50

3.10

 

25.6

2.36

3.13

 

 

 

 

 

 

 

 

 

 

 

 

 

80

18.6

2.48

2.69

23.6

2.65

2.73

 

24.0

2.49

2.77

 

 

 

 

 

 

 

 

 

 

 

 

 

60

17.2

2.31

2.81

22.8

2.33

2.86

 

23.3

2.34

2.92

30

 

 

 

 

 

 

 

 

 

 

 

70

16.7

2.41

2.55

21.6

2.43

2.59

 

22.0

2.44

2.62

 

 

 

 

 

 

 

 

 

 

 

 

 

80

16.2

2.55

2.27

20.1

2.56

2.28

 

20.4

2.58

2.29

 

 

 

 

 

 

 

 

 

 

 

 

 

60

12.2

2.08

2.43

17.6

2.10

2.46

 

18.0

2.12

2.48

17

 

 

 

 

 

 

 

 

 

 

 

70

12.0

2.19

2.16

16.4

2.21

2.18

 

16.8

2.23

2.21

 

 

 

 

 

 

 

 

 

 

 

 

 

80

11.8

2.31

1.90

15.2

2.34

1.92

 

15.6

2.36

1.95

 

 

 

 

 

 

 

 

 

 

 

 

 

60

10.1

1.97

2.25

15.1

2.00

2.27

 

15.5

2.04

2.30

10

 

 

 

 

 

 

 

 

 

 

 

70

9.6

2.06

1.93

13.6

2.09

1.97

 

13.9

2.13

1.98

 

 

 

 

 

 

 

 

 

 

 

 

 

80

9.1

2.17

1.63

12.2

2.19

1.68

 

12.5

2.23

1.69

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

Air Handler

Coil

T.C.

S.C.

KW

 

 

 

 

 

F2RP/F2FP030

 

1.00

1.01

0.99

 

 

 

 

 

F2RP/F2FP036

 

1.00

1.01

0.99

 

 

 

 

 

 

G2FD035(S,H)14

1.00

1.01

0.99

 

 

 

 

 

 

G1HD036

1.00

1.01

0.99

 

 

 

 

 

 

G2FD036(S,H)17

1.00

1.01

0.99

 

 

 

 

 

 

G2FD036(S,H)21

0.99

1.00

0.99

 

 

 

 

 

 

G1UA036S14

1.00

1.01

0.99

 

 

 

 

 

 

G1FA036S14

1.00

1.01

0.99

 

 

 

 

 

 

G1UA036S17,21

1.00

1.01

0.99

 

 

 

 

 

 

G1FA036S17,21

1.00

1.01

0.99

 

 

 

 

 

Unitary Products Group