York SVY48 THRU 60 Air Handler Air Flow Data, High / Low Speed Cooling And Heat Pump Airflow

Models: AVY24 THRU 60 SVY48 THRU 60

1 10
Download 10 pages 14.94 Kb
Page 4
Image 4
Air Handler Air Flow Data

256819-YTG-J-1208

Air Handler Air Flow Data

HIGH / LOW SPEED COOLING AND HEAT PUMP AIRFLOW

 

 

 

CFM

 

 

JUMPER SETTINGS

 

24B

 

 

36C

 

 

 

 

 

High

 

Low

 

High

 

Low

COOL Tap

ADJ Tap

1088

 

707

 

1387

 

905

A

B

830

 

542

 

1151

 

753

B

B

948

 

617

 

1201

 

783

A

A

716

 

465

 

1009

 

657

B

A

854

 

556

 

1086

 

703

A

C

612

 

462

 

953

 

622

C

B

637

 

460

 

901

 

588

B

C

531

 

460

 

754

 

493

D

B

542

 

462

 

831

 

540

C

A

462

 

462

 

657

 

460

D

A

474

 

460

 

751

 

494

C

C

461

 

464

 

588

 

461

D

C

 

48D

 

 

60D

JUMPER SETTINGS

High

 

Low

 

High

 

Low

COOL Tap

ADJ Tap

2138

 

1442

 

2364

 

1545

A

B

1759

 

1162

 

1962

 

1271

B

B

2009

 

1311

 

2123

 

1374

A

A

1612

 

1052

 

1763

 

1146

B

A

1773

 

1166

 

1905

 

1237

A

C

1530

 

989

 

1777

 

1158

C

B

1459

 

947

 

1580

 

1021

B

C

1359

 

886

 

1596

 

1030

D

B

1388

 

904

 

1583

 

1019

C

A

1221

 

806

 

1413

 

929

D

A

1244

 

808

 

1412

 

926

C

C

1118

 

715

 

1277

 

841

D

C

HIGH / LOW SPEED ELECTRIC HEAT AIRFLOW

 

 

 

CFM

 

 

JUMPER SETTINGS

 

24B

 

 

36C

 

 

 

 

 

High

 

Low

 

High

 

Low

HEAT Tap

ADJ Tap

1088

 

828

 

1387

 

908

A

N / A

954

 

714

 

1228

 

804

B

N / A

829

 

614

 

1151

 

756

C

N / A

678

 

523

 

923

 

609

D

N / A

 

48D

 

 

60D

JUMPER SETTINGS

High

 

Low

 

High

 

Low

HEAT Tap

ADJ Tap

2111

 

1417

 

2363

 

1488

A

N / A

1858

 

1252

 

2174

 

1252

B

N / A

1480

 

985

 

1868

 

1061

C

N / A

1250

 

840

 

1387

 

823

D

N / A

1.Airflow at nominal voltage, bottom return at 0.5 external static pressure, tested without filter installed, dry coil conditions.

2.These units have variable speed motors that automatically adjust to provide constant CFM from 0.0” to 0.6” w.c. static pressure.

3.From 0.6” to 1.0” static pressure, CFM is reduced by 2% per 0.1” increase in static.

4.Operation on duct systems with greater than 1.0” w.c. external static pressure is not recommended.

5.Both the COOL and the ADJUST tap must be set to obtain the cooling airflow desired (CFM).

6.The ADJ tap does not affect the HEAT tap setting.

7.Fan only airflow (CFM) = 63% of jumper selected COOL tap and ADJUST tap.

8.Low speed cooling used only with two stage outdoor units. (Speed is preset to 65% of high speed).

9.Dehumidification speed is 85% of jumper selected COOL tap and ADJUST tap.

10.When operating in both heat pump and electric heat modes, the airflow (CFM) will be per HEAT Tap CFM values only.

11.At some settings, LOW COOL and/or LOW HEAT airflow may be lower than what is required to operate an airflow switch on certain models of electronic air cleaners. Consult the instructions for the electronic air cleaner for further details.

12.Airflow (CFM) indicator light (LED2) flashes once for every 100 CFM (i.e.: 12 Flashes is 1200 CFM) – blinks are approximate +/- 10%.

4

Johnson Controls Unitary Products

Page 4
Image 4
York SVY48 THRU 60, AVY24 THRU 60 specifications Air Handler Air Flow Data, High / Low Speed Cooling And Heat Pump Airflow