York PC specifications Add - On Coils For Use With Split-System, Cooling & Heat Pumps, Features

Models: FC HC HD MC PC UC

1 16
Download 16 pages 8.66 Kb
Page 1
Image 1
TECHNICAL
Due to continuous product improvement, specifications are subject to change without notice.
ISO 9001
Certified Quality
Management System
Insulated Cabinet -

TECHNICAL

GUIDE

ADD - ON COILS

FOR USE WITH SPLIT-SYSTEM

COOLING & HEAT PUMPS

MODELS: MC, PC, FC, HD, HC, UC 600 - 2000 CFM 1.5 - 5 TON COILS

HORIZONTAL

FULL CASED

DUCT

MULTI-POSITION

HD

MC

UPFLOW UNCASED

UC

UPFLOW/DOWNFLOW

FULL CASED

FC

 

UPFLOW

HORIZONTAL CASED

PARTIAL CASED

HC

PC

258931-BTG-A-0606

DESCRIPTION

These cooling and heat pump coils are designed to be installed with UPG furnaces and to be matched with UPG cooling and heat pump outdoor units. All UPG coils utilize a TXV to provide our customers with the optimum performance and refrigerant control required for 13+ SEER systems. Coils can be ordered with a R22 TXV factory installed that can be easily converted to R410A by changing the bolt- on TXV.

“Flex-coils” are also available without a factory installed metering device. For added application flexibility a R22 or R410A TXV is installed, on “Flex-coils”, in the field to meet your refrigerant choice. Upflow/Downflow Coils Full Cased and Partial Cased Coils – Designed for high-efficiency to match any system, full cased in the upflow or downflow and the partial cased in the upflow only application.

Multi-Position Coils - Designed for high-efficiency like the upflow/downflow coil but with the added flexibility that allows it to be installed any position, upflow, downflow, horizontal right or left. This coil can be easily applied to our furnace and modular air handler in any configuration.

Horizontal Duct Coils - Available for both cooling and heat pump dedicated horizontal, slab coil, applications. Field transition may be required.

Dedicated Horizontal Cased Coils – These coils are cooling only or heat pump approved for horizontal furnace or modular air handler applications. Unlike the horizontal duct coils these cased coils match the dimensions of the furnace or modular blower.

FEATURES

Thermal Expansion Valve - Provides flexibility to convert any coil to R22 or R410A refrigerant. A true bolt-on TXV, valve assembly and equalizer tube are bolt-on, no brazing required. TXV and sens- ing bulb are mounted inside the cased coil cabinet. (Must be field supplied for all “Flex-coils”)

MicroBlue™ Coated Fins - All coils are treated with a MicroBlue™ Hydrophilic coating to enhance the removal of conden- sate during the refrigeration cycle and reduce the possibility of water blow-off. The MicroBlue™ coating also reduces the growth of germ causing microbes.

All evaporator coil cabinets are thermally

insulated with foil faced insulation to prevent sweating.

Internally Clean - All evaporator coils are factory leak-tested, dehydrated, sealed and shipped with a holding charge. The suction and liquid lines are sealed with rubber plugs, no cutting of connection stubs to attach line set.

Durable Finish Inside and Out - Coil casings are made of pre- painted steel. The pre-treated flat galvanized steel provides a better paint to steel bond, which resists corrosion and rust creep. All inter- nal metal parts are made of G90 pre-painted steel i.e. triangular plates, top plates, horizontal supports etc. (Coil header plates are non-painted due to the brazing process during production.)

Optimum Heat Transfer - Using the latest in heat transfer tech- nology, staggered rows of copper tubes are mechanically expanded into aluminum fins to provide optimum air to surface contact for ample moisture removal as well as high performance ratings.

 

ACCESSORIES

Visit us on the web at www.york.com for the most

Refer to Price Manual for specific model numbers.

up-to-date technical information.

TXV Kits - Thermal expansion valve kits are available for “Flex-coil”

Additional rating information can be found at

applications and converting R22 to R410A refrigerant or as a service

replacement. All TXV kits are non-braze,all connections are bolt-on

www.ariprimenet.org.

including the valve assembly and equalizer tube. (No orifice or any

 

 

other metering device is to used in conjunction with the TXV).

 

Coil Casing Without Coil – Coil casings are available in each

 

width that can be installed with the furnace or modular air handler

 

during initial installation. This option is available to allow the installer

 

the flexibility to install the coil at a later date without duct modifica-

 

tions.

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE