258931-BTG-A-0606

 

20

3/8”

 

 

 

(Opening)

 

 

 

C

 

 

(Opening)

B

 

 

 

 

12”

A

 

22”

 

 

 

 

D

 

 

20￿1/4”

 

 

BOTTOM

 

 

OPENING

 

 

DIMENSIONS

Coil - PC

Dimensions - PC Coils

 

 

 

 

 

Refrigerant

Factory

 

 

 

 

 

 

 

Model

A

B

C

D

Line Size*

Installed

 

 

 

 

 

 

 

TXV (R22)

 

 

 

 

 

Liquid

Vapor

 

 

 

 

 

 

 

 

PC18A2AN1

14.5

17 3/4

13 3/8

13.5

3/8

3/4

2A

 

 

 

 

 

 

 

 

PC18A3XN1

14.5

17 3/4

13 3/8

13.5

3/8

3/4

None

 

 

 

 

 

 

 

 

PC18B2AN1

17.5

17

16 3/8

16.5

3/8

3/4

2A

 

 

 

 

 

 

 

 

PC18B3XN1

17.5

17

16 3/8

16.5

3/8

3/4

None

 

 

 

 

 

 

 

 

PC24A2AN1

14.5

21 7/8

13 3/8

13.5

3/8

3/4

2A

 

 

 

 

 

 

 

 

PC24A3XN1

14.5

21 7/8

13 3/8

13.5

3/8

3/4

None

 

 

 

 

 

 

 

 

PC24B2AN1

17.5

21 3/8

16 3/8

16.5

3/8

3/4

2A

 

 

 

 

 

 

 

 

PC24B3XN1

17.5

21 3/8

16 3/8

16.5

3/8

3/4

None

 

 

 

 

 

 

 

 

PC30A2AN1

14.5

21 7/8

13 3/8

13.5

3/8

3/4

2A

 

 

 

 

 

 

 

 

PC30A3XN1

14.5

21 7/8

13 3/8

13.5

3/8

3/4

None

 

 

 

 

 

 

 

 

PC30B2AN1

17.5

21 3/8

16 3/8

16.5

3/8

3/4

2A

 

 

 

 

 

 

 

 

PC30B3XN1

17.5

21 3/8

16 3/8

16.5

3/8

3/4

None

 

 

 

 

 

 

 

 

PC35B3XN1

17.5

18 7/8

16 3/8

16.5

3/8

3/4

None

 

 

 

 

 

 

 

 

PC35C3XN1

21

18 3/4

19 7/8

20

3/8

3/4

None

 

 

 

 

 

 

 

 

PC36A2AN1

14.5

23 7/8

13 3/8

13.5

3/8

7/8

2A

 

 

 

 

 

 

 

 

PC36A3XN1

14.5

23 7/8

13 3/8

13.5

3/8

7/8

None

 

 

 

 

 

 

 

 

PC36B2AN1

17.5

23 1/8

16 3/8

16.5

3/8

7/8

2A

 

 

 

 

 

 

 

 

PC36B3XN1

17.5

23 1/8

16 3/8

16.5

3/8

7/8

None

 

 

 

 

 

 

 

 

PC36C2AN1

21

22 7/8

19 7/8

20

3/8

7/8

2A

 

 

 

 

 

 

 

 

PC36C3XN1

21

22 7/8

19 7/8

20

3/8

7/8

None

 

 

 

 

 

 

 

 

PC42B2CN1

17.5

27 5/8

16 3/8

16.5

3/8

7/8

2C

 

 

 

 

 

 

 

 

PC42B3XN1

17.5

27 5/8

16 3/8

16.5

3/8

7/8

None

 

 

 

 

 

 

 

 

PC42C2CN1

21

27 1/8

19 7/8

20

3/8

7/8

2C

 

 

 

 

 

 

 

 

PC42C3XN1

21

27 1/8

19 7/8

20

3/8

7/8

None

 

 

 

 

 

 

 

 

PC48C2CN1

21

25 3/8

19 7/8

20

3/8

7/8

2C

 

 

 

 

 

 

 

 

PC48C3XN1

21

25 3/8

19 7/8

20

3/8

7/8

None

 

 

 

 

 

 

 

 

PC48D2CN1

24.5

24 5/8

23 3/8

23.5

3/8

7/8

2C

 

 

 

 

 

 

 

 

PC48D3XN1

24.5

24 5/8

23 3/8

23.5

3/8

7/8

None

 

 

 

 

 

 

 

 

PC60C2CN1

21

27 1/2

19 7/8

20

3/8

7/8

2C

 

 

 

 

 

 

 

 

PC60C3XN1

21

27 1/2

19 7/8

20

3/8

7/8

None

 

 

 

 

 

 

 

 

PC60D2CN1

24.5

26 7/8

23 3/8

23.5

3/8

7/8

2C

 

 

 

 

 

 

 

 

PC60D3XN1

24.5

26 7/8

23 3/8

23.5

3/8

7/8

None

 

 

 

 

 

 

 

 

PC coils are not available with a factory installed horizontal drain pan. (3X) = Models require field installed TXV.

*Refrigerant line sizes may require larger lines for extended line lengths. See York bulletin #690.01-AD1V for details.

C

B

A

COIL - UC

Dimensions - UC Coils

 

 

Dimensions — Inches

 

Refrigerant Connections

 

 

 

 

 

 

 

Model

 

 

 

Line Size

 

 

A

B

C

 

 

 

 

 

Liquid

Vapor

 

 

 

 

 

 

 

 

 

 

 

 

 

UC18A3XN1

 

 

 

 

 

 

13

 

17

 

 

 

 

 

 

 

 

UC18A2AN1

 

 

 

 

 

 

 

 

 

 

 

UC18B3XN1

 

 

 

 

 

 

16

 

16.5

 

 

 

 

 

 

 

 

UC18B2AN1

 

 

 

 

 

 

 

 

 

 

 

UC24A3XN1

 

 

 

 

 

 

13

 

21

 

 

 

 

 

 

 

 

UC24A2AN1

 

 

 

 

3/4

 

 

 

 

 

 

 

UC24B3XN1

 

 

 

 

 

 

 

 

 

 

16

 

20.5

 

 

 

 

 

 

 

 

UC24B2AN1

 

 

 

 

 

 

 

 

 

 

 

UC30A3XN1

 

 

 

 

 

 

13

 

21

 

 

 

 

 

 

 

 

UC30A2AN1

 

 

 

 

 

 

 

 

 

 

 

UC30B3XN1

 

 

 

 

 

 

16

 

20.5

 

 

 

 

 

 

 

 

UC30B2AN1

 

 

 

 

 

 

 

 

 

 

 

UC36A3XN1

 

 

 

 

 

 

13

 

23.5

 

 

 

 

 

 

 

 

UC36A2AN1

 

 

 

 

 

 

 

 

 

 

 

UC36B3XN1

 

 

 

 

 

 

16

19.875

22.5

3/8

 

 

 

UC36B2AN1

UC36C3XN1

19.522

UC36C2AN1

 

 

 

 

 

 

 

 

UC42B3XN1

 

 

 

 

16

26.5

 

 

 

UC42B2CN1

 

 

 

 

 

 

 

UC42C3XN1

 

 

 

 

19.5

25.5

7/8

 

UC42C2CN1

UC48C3XN1

19.523.5

UC48C2CN1

UC48D3XN1

23

23

UC48D2CN1

UC60C3XN1

19.525.5

UC60C2CN1

UC60D3XN1

23

25

UC60D2CN1

12

Unitary Products Group

Page 12
Image 12
York MC, HD, HC, FC specifications Coil PC Dimensions PC Coils, Coil UC, Dimensions UC Coils

FC, HC, HD, MC, PC specifications

York, a renowned name in the HVAC industry, has made significant strides with its line of packaged units, specifically the PC, UC, MC, HD, and HC series. These units are designed to cater to various heating and cooling requirements across residential and commercial applications.

The York PC series, or Packaged Cooling units, encompass a range of air conditioning systems known for their compact design and efficiency. Ideal for smaller spaces, these units feature advanced technology, including variable speed compressors that optimize energy consumption and enhance comfort levels. With a robust construction, they offer durability and reliability, ensuring longevity in performance.

The UC series, or Unitary Cooling units, are designed for larger applications. They utilize state-of-the-art refrigerant systems that not only boost performance but also adhere to stringent environmental regulations. The UC units provide significant energy savings through high-efficiency designs and intelligent controls, which help in optimizing operation during varying load conditions.

Moving on to the MC series, the Multi-Climate units are versatile, providing both heating and cooling capabilities. They are engineered with innovative heat pump technology, allowing for year-round climate control. The MC units come with multi-zone capability, ensuring customized comfort for different areas of a property. Additionally, they incorporate smart connectivity options, enabling remote monitoring and management through mobile applications.

The HD series, or High-Demand units, are tailored for environments that require robust performance under heavy loads. These units come equipped with high-efficiency motors and enhanced airflow designs, ensuring optimal performance even under extreme conditions. Their rugged construction makes them ideal for industrial settings, where reliability is paramount.

Finally, the HC series, or Hybrid Cooling units, combine traditional systems with modern advancements in technology. These units operate on both electrical and gas power, providing flexibility and efficiency. They are perfect for areas with fluctuating energy costs, allowing users to switch between energy sources as needed. The HC series also features advanced control systems, enabling precise temperature regulation and energy management.

In summary, York's PC, UC, MC, HD, and HC series encapsulate a comprehensive range of HVAC solutions, emphasizing energy efficiency, durability, and advanced technology. Each series offers unique features tailored to meet the diverse needs of consumers, ensuring comfort and reliability for both residential and commercial spaces. With a commitment to innovation and quality, York continues to be a leader in the HVAC market.